Siemens 3RW4458-6BC36 — Soft Starters

Siemens 3RW4458-6BC36 Soft Starter, 1680 A, 690 V, SIRIUS

MPN3RW4458-6BC36

Siemens SIRIUS 3RW4458-6BC36 soft starter, 1680 A at 40 °C, 690 V rated insulation voltage, 50/60 Hz, integrated bypass, inside-delta circuit, screw fixing.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4458-6BC36 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4458-6BC36 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C1 680A
Rated operational current at 50 °C1 472A
Rated operational current at 60 °C1 316A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4458-6BC36 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz115V
Rated voltage at 60 Hz115V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4458-6BC36 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4458-6BC36 — Mechanical
ParameterValue
Height640mm
Width510mm
Depth290mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4458-6BC36 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

1680 A at 40 °C — sizing the main power path and the bypass

The 3RW4458-6BC36: At 50 °C the rating drops to 1472 A, and at 60 °C it falls to 1316 A — the derating curve matters if the soft starter lives inside a closed panel near a furnace line or a hot-strip mill stand. The integrated bypass contact system eliminates the need for an external bypass contactor, saving panel space and reducing the wiring count — the thyristors are shorted out after the start, so the heat load in steady state is just the bypass contact resistance. Inside-delta circuit capability means the motor windings can be configured in delta and the soft starter connected in series with each winding, reducing the current through the soft starter to 58% of the line current — useful when the motor FLA exceeds the soft starter's rating.

Termination and cable entry — what fits the lugs

The main current circuit terminates via busbar connection; the power cable lugs accept stranded copper from 70 to 240 mm² and finely stranded from 50 to 240 mm². For US wire gauge equivalents, the main contacts accept 2/0 to 500 kcmil — covers the range from 2/0 AWG up to 500 MCM.

Mounting and clearances — fitting it into the panel

The unit measures 640 mm high by 510 mm wide by 290 mm deep and is fastened by screw fixing to a backplate — it does not snap onto a DIN rail. Mounting position allows a vertical surface with ±90° rotation and ±22.5° tilt forward or backward — useful when the panel layout forces an angled installation. Required clearances: 100 mm above, 75 mm below, and only 5 mm at the sides — the tight side clearance lets you pack units side-by-side, but the vertical clearance is non-negotiable for cable bending radius and airflow.

Protection and diagnostics — what's built in

Motor overload protection is integrated, so no separate overload relay is needed in the motor circuit — the thermal model protects the motor and the thyristors (intrinsic device protection,). Adjustable current limitation lets you set the starting torque from 8% of motor FLA (minimum load,) up to whatever the motor can handle — critical for soft-starting a loaded conveyor without tripping upstream. A display shows fault signals locally — no need to plug in a laptop to read the last trip cause. External reset input allows remote clearing of latched faults from a PLC or pushbutton station.

Environmental and compliance — industrial-grade construction

Pollution degree 3 per IEC 60947-4-2 — the soft starter is designed for conductive dust and industrial atmospheres, not just clean control rooms. Operating frequency is 50/60 Hz — the same unit works on either grid without a hardware change. Storage temperature range -25 to +80 °C; operating ambient up to 60 °C with derating starting at 40 °C.

Frequently asked questions

What is the maximum motor cable length for 3RW4458-6BC36?

The maximum wire length is 500 m — beyond that, voltage drop and reflected wave effects on the motor terminals must be evaluated.

MPN
3RW4458-6BC36