Siemens 3RW4466-2BC34 — Soft Starters

Siemens 3RW4466-2BC34 Soft Starter, 2103 A, 690 V, SIRIUS

MPN3RW4466-2BC34

Siemens SIRIUS 3RW4466-2BC34 soft starter, 2103 A at 40 °C, 690 V insulation voltage, integrated bypass contactor, inside-delta circuit capable, 780 x 575 x 292 mm.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4466-2BC34 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4466-2BC34 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C2 103A
Rated operational current at 50 °C1 864A
Rated operational current at 60 °C1 680A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4466-2BC34 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz115V
Rated voltage at 60 Hz115V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4466-2BC34 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4466-2BC34 — Mechanical
ParameterValue
Height780mm
Width575mm
Depth292mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4466-2BC34 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

2103 A at 40 °C — sizing this soft starter for the motor

The 3RW4466-2BC34: The headline rating is 2103 A at 40 °C ambient, which sets the maximum motor full-load current this unit can start and run through the bypass. Derate to 1864 A at 50 °C and 1680 A at 60 °C — if the panel ambient runs hot, the usable motor size drops accordingly. The operating frequency covers 50 to 60 Hz with a single control supply voltage of 115 V at both frequencies — one transformer covers the control circuit regardless of line frequency. Minimum load is 8 % of the rated current — useful if you're starting an unloaded conveyor or pump with low breakaway torque; the soft starter won't trip on undercurrent during the start ramp.

Integrated bypass — what it saves in the panel

The integrated bypass contactor means you don't add a separate bypass contactor and wire it across the soft starter. That saves a mounting footprint, control wiring, and a coil driver output in the PLC. The bypass carries the full motor current once the start ramp completes, taking the heat off the thyristors. Inside-delta circuit wiring is supported — if the motor has six leads accessible, wiring the soft starter in the delta legs reduces the current the unit sees by a factor of 1.73. That lets a smaller-frame soft starter handle a given motor, but the motor must be six-lead accessible and the starter configured for inside-delta operation. Main circuit connections accept busbar, cable lugs from 70 to 240 mm² stranded or 50 to 240 mm² finely stranded, and 2/0 to 500 kcmil for North American installations. The auxiliary and control circuit terminals are spring-loaded — strip, push, done, no torque driver needed.

Mounting and environment — where this unit fits

Dimensions are 780 mm high by 575 mm wide by 292 mm deep — this is a large-frame soft starter, not a panel-board component. Mounting is screw-fixed to a vertical surface, with ±90° rotation and ±22.5° tilt front-to-back allowed. Plan the enclosure depth to clear the 292 mm plus the 100 mm upward and 75 mm downward clearance for ventilation. Pollution degree 3 per IEC 60947-4-2 means it's rated for industrial environments where conductive dust or occasional condensation occurs — no need for a filtered enclosure in most factory-floor settings. Operating temperature range is 60 °C max during operation, storage from -25 to +80 °C. Maximum motor cable length is 500 m — if the motor is far from the starter, keep the cable run under that limit to avoid reflected-wave voltage spikes that can stress the motor insulation.

Protection and control features

Motor overload protection is built in, along with intrinsic device protection — the soft starter monitors its own thyristor temperature and current, so it can shut down before damaging itself. Adjustable current limitation lets you set the start current between the minimum load threshold and the unit's full rating, useful for limiting inrush on weak supply lines or protecting driven equipment. External reset input is present, and the display shows fault signals — no need to carry a laptop to read the last trip cause. A motor brake output is included as a product component, which simplifies wiring for applications that need a DC injection brake after the stop ramp.

Frequently asked questions

How do I get current pricing and availability for 3RW4466-2BC34?

Submit an RFQ through this listing. The unit is sourced through authorized distribution channels.

What are the main circuit connection options for this soft starter?

The main current circuit accepts busbar connections, stranded cable from 70 to 240 mm², finely stranded from 50 to 240 mm², and North American kcmil sizes from 2/0 to 500 kcmil.

Does this soft starter include a bypass contactor?

Yes, the integrated bypass contactor is built in. You do not need to add a separate bypass contactor — the unit carries the full motor current through the bypass once the start ramp completes, removing heat from the thyristors during continuous running.

MPN
3RW4466-2BC34