Siemens 3RW4466-6BC34 — Soft Starters

Siemens 3RW4466-6BC34 SIRIUS Soft Starter, 2103 A, 690 V

MPN3RW4466-6BC34

Siemens SIRIUS 3RW4466-6BC34 soft starter, 2103 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass, thyristor control, screw fixing.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4466-6BC34 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4466-6BC34 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C2 103A
Rated operational current at 50 °C1 864A
Rated operational current at 60 °C1 680A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4466-6BC34 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz115V
Rated voltage at 60 Hz115V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4466-6BC34 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4466-6BC34 — Mechanical
ParameterValue
Height780mm
Width575mm
Depth292mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4466-6BC34 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Physical footprint and panel fit

The 3RW4466-6BC34 measures 780 mm high by 575 mm wide by 292 mm deep — a substantial cabinet footprint that demands a dedicated backplate section, not a DIN-rail clip. Clearance zones are specified: 100 mm above, 75 mm below, and just 5 mm at the sides. The top clearance is the critical dimension for hot air exhaust from the thyristor stack — skimping on that 100 mm ceiling drives the unit into early thermal derating.

Current ratings and thermal derating profile

The 40 °C figure is the catalog rating; if the panel ambient runs hotter — common in a packed MCC lineup — the 60 °C derating to 1680 A is the number to size the motor branch circuit against. The derating temperature floor is 40 °C, meaning the full 2103 A is available only when the cooling air entering the unit stays at or below that point. Above 40 °C, the thyristor junction temperature limits the continuous current per the published steps.

Power and control wiring terminals

Main circuit connection is via busbar, with the cable terminal range accepting stranded 70–240 mm² and finely stranded 50–240 mm², plus AWG 2/0–500 kcmil for the main contacts. That covers everything from 2/0 feeder to 500 kcmil for the high-current path — no adapter lugs needed for the common industrial sizes.

Protection and control features built in

Motor overload protection, intrinsic device protection (thyristor overtemperature, phase imbalance), and adjustable current limitation are all integrated — no separate overload relay needed in the branch circuit. The minimum load is 8 % of the rated current, so it handles lightly loaded motors without dropping out. An integrated bypass contact system means the thyristors are shorted out once the motor reaches full speed, eliminating continuous conduction losses in the power semiconductors. The unit also includes a motor brake output and an external reset input for remote fault clearing.

Environmental and compliance ratings

Pollution degree 3 per IEC 60947-4-2 — suitable for industrial environments with conductive dust or occasional condensation. Insulation voltage rated 690 V, operating frequency 50–60 Hz. Storage temperature range -25 to +80 °C, with a 60 °C maximum during operation. The maximum motor cable length is 500 m — sufficient for most distributed motor installations without output reactors, though longer runs may require a dv/dt filter depending on the cable capacitance and the thyristor switching edge.

Frequently asked questions

What is the maximum continuous current at 60 °C ambient?

At 60 °C ambient the unit is rated 1680 A continuous. The 2103 A catalog rating applies only at 40 °C; above that temperature the thyristor junction limits the output per the published derating step.

MPN
3RW4466-6BC34