Siemens 3RW4466-6BC35 — Soft Starters

Siemens 3RW4466-6BC35 SIRIUS Soft Starter, 2103 A at 40 °C

MPN3RW4466-6BC35

Siemens SIRIUS 3RW4466-6BC35 soft starter, 2103 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass, inside-delta circuit, screw fixing, 575 x 780 x 292 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4466-6BC35 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4466-6BC35 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C2 103A
Rated operational current at 50 °C1 864A
Rated operational current at 60 °C1 680A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4466-6BC35 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz115V
Rated voltage at 60 Hz115V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4466-6BC35 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4466-6BC35 — Mechanical
ParameterValue
Height780mm
Width575mm
Depth292mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4466-6BC35 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

2103 A at 40 °C — what that current rating means for your motor

The 3RW4466-6BC35: This SIRIUS soft starter is rated 2103 A at 40 °C ambient. That's the continuous motor current it can handle in a standard industrial enclosure with the bypass closed — the thyristors are only in circuit during the start and stop ramp. At 50 °C the rating drops to 1864 A, and at 60 °C it's 1680 A. Operating frequency is 50/60 Hz, so it covers both line frequencies without a setting change.

Integrated bypass and inside-delta wiring — what it saves you

The integrated bypass contact system means once the motor is up to speed, the thyristors are shorted out. No external bypass contactor to buy, wire, or coordinate. That saves panel space and a couple of hours of wiring time. Inside-delta circuit capability lets you connect the soft starter in the delta legs of a six-lead motor. That drops the current through the thyristors to 58% of the line current — effectively letting a 2103 A unit handle a motor with a higher FLA than the nameplate suggests. Useful when you're pushing the limit on an existing starter frame. It also has an adjustable current limitation and a minimum load setting down to 8%, so it can start lightly loaded conveyors or pumps without the ramp overshooting.

Panel fit — 575 mm wide, 780 mm tall, 292 mm deep

The enclosure is 575 mm wide by 780 mm high by 292 mm deep. That's a substantial footprint — you're not squeezing this into a shallow wall-mount box. Plan for a floor-standing enclosure or a deep back panel. Mounting is screw fixing, not DIN rail, so you'll drill and tap the backplate. Mounting position is flexible: vertical surface, rotatable ±90°, and tiltable ±22.5° front/back. That helps when the enclosure layout forces an off-angle install — just keep the cooling airflow path clear. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides.

Main circuit wiring — busbar or big cable

The main current circuit connection is busbar. For the cable option, the terminal accepts stranded 70–240 mm², finely stranded 50–240 mm², or AWG 2/0–500 kcmil. That's serious copper — plan your lug kit and torque wrench accordingly.

Protection and diagnostics built in

Motor overload protection and intrinsic device protection are onboard — you don't need a separate overload relay in the starter circuit. The fault signal has a display, so when it trips you get a code, not a blank stare. External reset lets you clear faults from a remote pushbutton or PLC output without opening the panel door. The thyristors handle the switching; no mechanical contacts to weld or pit during starts. Max motor cable length is 500 m — long enough for most plant-floor runs to the motor. Storage temperature range is -25 to +80 °C, operating ambient max 60 °C.