Siemens 3RW5056-2AB14 — Soft Starters

Siemens 3RW5056-2AB14 Soft Starter, 81 A Min, 200-480 V

MPN3RW5056-2AB14
Active

Siemens 3RW5056-2AB14 SIRIUS soft starter, 81 A minimum, 200-480 V rated voltage, ATEX/UKEX/IECEx certified, Class 10A/10E/20E trip, hybrid switching device, screw fixing.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5056-2AB14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5056-2AB14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)90 kW
Rated motor power at 230 V (40 °C)45 kW
Rated operational current at 40 °C171 A
Rated operational current at 50 °C153 A
Rated operational current at 60 °C141 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)1 478 W
3RW5056-2AB14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5056-2AB14 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5056-2AB14 — Mechanical
ParameterValue
Height198 mm
Width120 mm
Depth249 mm
Weight5.2 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5056-2AB14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5056-2AB14 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5056-2AB14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Hazardous-area certifications — ATEX, UKEX, IECEx

ATEX, UKEX, and IECEx are all listed as Yes — the 3RW5056-2AB14 carries the three main explosive-atmosphere certifications. That means it can be installed in Zone 1 or Zone 2 gas groups and Zone 21 or Zone 22 dust areas per IEC 60079-14, provided the rest of the installation follows the same protection concept. The UKEX mark covers Great Britain post-Brexit; IECEx gives international acceptance without retesting.

Rated voltage 200-480 V — motor voltage coverage

Rated voltage is 200 to 480 V AC, covering the common low-voltage motor systems worldwide: 208 V, 230 V, 400 V, 460 V, and 480 V. The minimum motor full-load current is 81 A — that sets the floor for the motor FLC this frame can handle. The control supply is 110-250 V AC at 50 or 60 Hz, so a single control transformer covers both 120 V and 240 V control circuits.

Trip class and starting profiles

Trip class is selectable: CLASS 10A, 10E (preset), or 20E per IEC 60947-4-2. Class 10A clears an overload in 10 seconds at 7.2× Ie — suited for normal-start loads like pumps and fans. The preset 10E is the default out of the box.

Fieldbus integration — PROFIBUS, Modbus, EtherNet/IP

The soft starter supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. That covers the three dominant industrial Ethernet protocols plus the legacy fieldbus. PROFIenergy is available when used with the PROFINET communication module — useful for energy management in automated lines. The analog output is 4-20 mA (default) or 0-10 V (parameterizable with the High Feature HMI), giving a speed or current signal back to the PLC.

Mounting clearances and panel fit

Dimensions are 249 mm deep, 120 mm wide, 198 mm high. Screw fixing to the backplate or DIN rail. Clearance requirements: 100 mm above, 10 mm in front, 0 mm behind, 75 mm below, 5 mm at the sides. The zero backward clearance means it can sit flush against the panel back wall — useful in shallow enclosures.

Compliance and approvals — UL, CSA, CE

UL and CSA approvals are listed — the soft starter is accepted for North American installations without additional agency review. CE marking covers the European market. The product category is hybrid switching devices, meaning it combines semiconductor switching for the start ramp with a mechanical bypass contactor for steady-state running, reducing heat dissipation during continuous operation.

Frequently asked questions

What hazardous-area certifications does 3RW5056-2AB14 carry?

ATEX, UKEX, and IECEx are all listed as Yes. This covers explosive atmospheres per IEC 60079-14 for gas and dust zones, plus the UKCA-equivalent UKEX mark for Great Britain.