Skip to main content
Siemens 3RW5056-6TB04 — Soft Starters

Siemens 3RW5056-6TB04 Soft Starter, 81 A min, 200-480 V

MPN3RW5056-6TB04
Active

Siemens 3RW5056-6TB04 soft starter, 81 A minimum setting, 200-480 V rated, Trip Class 10A/10E/20E, ATEX/UKEX/IECEx, PROFIBUS/PROFINET/Modbus/EtherNet/IP, 249 x 120 x 198 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5056-6TB04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5056-6TB04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)90 kW
Rated motor power at 230 V (40 °C)45 kW
Rated operational current at 40 °C171 A
Rated operational current at 50 °C153 A
Rated operational current at 60 °C141 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)1 478 W
3RW5056-6TB04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5056-6TB04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5056-6TB04 — Mechanical
ParameterValue
Height198 mm
Width120 mm
Depth249 mm
Weight5.2 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5056-6TB04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5056-6TB04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5056-6TB04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

What the 81 A minimum setting and 200-480 V range mean for motor starting

The 3RW5056-6TB04: The 81 A minimum setting on the 200-480 V rated range means this soft starter covers the common low-voltage motor sizes from about 37 kW at 400 V up to roughly 55 kW at 480 V, depending on the service factor and starting duty. The voltage ramp, soft torque, and pump ramp down profiles give you tailored starting curves — soft torque reduces the initial current spike on belt-driven loads, pump ramp down eliminates water hammer on discharge lines. These are set via the integrated keypad or the fieldbus interface.

Fieldbus and hazardous-area certifications — one part for global panels

This soft starter carries ATEX, UKEX, and IECEx certification — that is the full set for explosive atmospheres under the ATEX 2014/34/EU directive, UK SI 2016/1107, and the IECEx Scheme. It also holds UL and CSA approval, so it is accepted in North American panels without a separate evaluation. Same part, different passports — genuine is genuine regardless of which region's stock it came from. On the fieldbus side it speaks PROFIBUS, PROFINET standard with PROFIenergy support, Modbus RTU, Modbus TCP, and EtherNet/IP. That covers the five most common industrial Ethernet and serial protocols — no gateway needed for a Siemens S7-1500, Rockwell CompactLogix, or Modbus TCP controller.

Mounting, clearance, and operating temperature — panel-fit constraints

The unit measures 249 mm deep, 120 mm wide, and 198 mm high — a standard DIN-rail footprint with screw fixing. The clearance requirements are specific: 100 mm upwards, 10 mm forwards, 75 mm downwards, 5 mm at the sides, and 0 mm backwards. That upward clearance is the tightest constraint — plan the gland plate and cable duct accordingly. The mounting position allows vertical surface mounting with ±90° rotation and ±22.5° tilt front-to-back, which gives flexibility in tight enclosures.

Same genuine Siemens part, different passport: the unit carries the same certifications regardless of which authorized region's stock it ships from.

Frequently asked questions

What ATEX and UKEX certifications does 3RW5056-6TB04 carry?

It carries ATEX, UKEX, and IECEx certification, plus UL and CSA approval — covering hazardous-area installations under EU, UK, and IEC schemes as well as North American panels.

What fieldbus protocols does 3RW5056-6TB04 support?

It supports PROFIBUS, PROFINET standard with PROFIenergy, Modbus RTU, Modbus TCP, and EtherNet/IP — five protocols covering Siemens, Rockwell, and Modbus TCP controllers without a gateway.

MPN
3RW5056-6TB04