Siemens 3RW5056-6TB14 Soft Starter, 81 A, 200-480 V, ATEX

MPN3RW5056-6TB14
Active

Siemens SIRIUS 3RW5056-6TB14 soft starter, 81 A minimum, 200-480 V, screw fixing, ATEX/IECEx, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, Trip Class 10A/10E/20E.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5056-6TB14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5056-6TB14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)90 kW
Rated motor power at 230 V (40 °C)45 kW
Rated operational current at 40 °C171 A
Rated operational current at 50 °C153 A
Rated operational current at 60 °C141 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)1 478 W
3RW5056-6TB14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5056-6TB14 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5056-6TB14 — Mechanical
ParameterValue
Height198 mm
Width120 mm
Depth249 mm
Weight5.2 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5056-6TB14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5056-6TB14 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5056-6TB14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

81 A minimum, 200-480 V — motor starting for ATEX zones

The Siemens 3RW5056-6TB14 is a SIRIUS soft starter with a minimum rated current of 81 A and a rated voltage of 200 to 480 V, making it suitable for medium-sized induction motors in applications requiring controlled acceleration and deceleration. Its Trip Class is preset to CLASS 10A / 10E, with CLASS 20E selectable per IEC 60947-4-2, meaning it protects the motor during start-up by limiting thermal stress — CLASS 10A is typical for standard starts, while CLASS 20E allows longer acceleration for high-inertia loads. The unit carries ATEX and IECEx certification, so it can be installed in potentially explosive atmospheres — a key differentiator from standard soft starters that lack hazardous-area approvals. This makes it a fit for chemical, oil-and-gas, or grain-handling lines where the starter must sit in or near the classified zone.

The 3RW5056-6TB14 mounts via screw fixing to a vertical surface, with the mounting surface rotatable ±90° and tiltable ±22.5° to the front and back. Clearance requirements: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, and 5 mm at the side — plan these gaps into the panel layout to avoid derating or airflow restriction. Dimensions are 120 mm wide, 198 mm high, and 249 mm deep. Shock resistance is rated at 15 g / 11 ms, dropping to 12 g / 11 ms with potential contact lifting — ensure the mounting bracket and panel are rigid enough to avoid exceeding these limits in high-vibration environments.

Approvals include CE marking, UL approval, and CSA approval, covering the major North American and European regulatory jurisdictions. No official successor or replacement is listed — this is the active variant for new designs.

Frequently asked questions

What is the rated current of Siemens 3RW5056-6TB14 soft starter?

The minimum rated current is 81 A, with a rated voltage of 200 to 480 V. The Trip Class is preset to CLASS 10A / 10E, with CLASS 20E selectable per IEC 60947-4-2.

Does the 3RW5056-6TB14 support PROFIBUS and Modbus?

Yes, it supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP, giving flexibility across Siemens and Rockwell automation environments.

What is 3RW5056-6TB14's ATEX certification?

It carries ATEX and IECEx certification, allowing installation in potentially explosive atmospheres — a key feature for hazardous-area motor starting.

Where can I buy the Siemens 3RW5056-6TB14 soft starter?

This part is sourced to order; availability and pricing are confirmed at the time of quote.

MPN
3RW5056-6TB14