Siemens 3RW5072-2TB15 — Soft Starters

Siemens 3RW5072-2TB15 Soft Starter, 90A Min, 200-600V, ATEX

MPN3RW5072-2TB15
Active

Siemens SIRIUS 3RW5072-2TB15 soft starter, 90 A minimum, 200-600 V, ATEX, IECEx, UL, CSA, CE, trip class 10A/10E/20E, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, screw fixing, 282 mm depth, 160 mm width, 230 mm height.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5072-2TB15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5072-2TB15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)110 kW
Rated motor power at 230 V (40 °C)55 kW
Rated operational current at 40 °C210 A
Rated operational current at 50 °C186 A
Rated operational current at 60 °C170 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)1 867 W
3RW5072-2TB15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5072-2TB15 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5072-2TB15 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5072-2TB15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5072-2TB15 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5072-2TB15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

What the 90 A minimum and 200-600 V mean for your motor circuit

The 3RW5072-2TB15: The 90 A minimum setting means this soft starter is sized for motor FLA down to that floor — anything smaller and the current resolution won't let you tune the ramp properly. Trip class 10A/10E (preset) / 20E per IEC 60947-4-2 gives you the choice: 10A for standard-start loads like pumps and fans, 10E for electronic overload matching, or 20E for high-inertia loads that need a longer acceleration ramp without nuisance tripping. The voltage ramp, soft torque, and pump ramp down features let you dial in the start profile — soft torque reduces mechanical shock on geared drives, pump ramp down prevents water hammer on discharge lines.

Fieldbus pick — PROFIBUS, Modbus, EtherNet/IP on one unit

This soft starter carries PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP onboard — no separate communication module needed for any of those four protocols. PROFIenergy is available when paired with the PROFINET standard communication module. The remote reset by cycling the control supply voltage means you can clear a fault from the PLC without a site visit — useful on remote pump stations or conveyor lines. Error logbook is supported, but only with special accessories — factor that into the BOM if you need event history for predictive maintenance.

ATEX, IECEx, and the hybrid switching device classification

ATEX and IECEx approval (both marked Yes) means this soft starter is certified for use in potentially explosive atmospheres — Zone 2 or Zone 22 typically, depending on the installation. The hybrid switching device category means it uses both electromechanical and semiconductor elements for the start sequence, then bypasses to the contactor for steady-state running. UL and CSA approval are both present, so it lands in North American panels without a separate evaluation. CE marking covers the European market. Service factor is 1 — no built-in overload margin beyond the set current. The minimum load is 15% relative to the smallest settable Ie, so don't try to run a fractional-horsepower motor through this unit.

Mounting and cooling — screw fixing, derating above 40 °C

Screw fixing to the mounting plate — no DIN rail snap-on here. The unit is 282 mm deep, 160 mm wide, 230 mm tall, with 100 mm clearance upwards, 10 mm forwards, 75 mm downwards, 5 mm at the sides, and 0 mm backwards. That 0 mm backwards means it can sit flush against the back panel. Mounting position is vertical with the mounting surface rotatable ±90° and tiltable ±22.5° front-to-back — gives flexibility in tight cabinets but keep the derating curve in mind if you tilt it. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if contact lifting is a concern — fine for most industrial panels but check if the application has repeated hammering or press impacts.

No official successor or cross-reference to the alternate MPNs listed (6ED1052-1MD08-0BA1, 6ES7517-3FP00-0AB0, 6ES7214-1BG40-0XB0) — those are from different Siemens product families (LOGO!, S7-1500, S7-1200) and are not functional replacements for a soft starter. The 3RW5072-2TB15 is the right part for the motor-starting BOM line.

Frequently asked questions

What ATEX and IECEx approvals does 3RW5072-2TB15 carry?

Both ATEX and IECEx are marked Yes — certified for use in potentially explosive atmospheres. Also carries UL, CSA, and CE approvals, covering North American and European regulatory jurisdictions.

What fieldbus protocols does 3RW5072-2TB15 support?

PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP are all onboard. PROFIenergy is available when used with the PROFINET standard communication module.

What are the mounting clearances for 3RW5072-2TB15?

100 mm upwards, 10 mm forwards, 75 mm downwards, 5 mm at the sides, 0 mm backwards — flush against the back panel. Screw fixing to the mounting plate; no DIN rail option.

MPN
3RW5072-2TB15