Skip to main content
Siemens 3RW5073-2AB14

Siemens 3RW5073-2AB14 Soft Starter, 200-480 V, 100 A Min

MPN 3RW5073-2AB14
Active

Siemens 3RW5073-2AB14 soft starter, 200-480 V rated voltage, 100 A minimum load, ATEX/UKEX/IECEx certified, Trip Class 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP, screw fixing, 160x230x282 mm.

$1,553.21 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5073-2AB14 specifications
ParameterValue
Mountingscrew fixing
Depth282 mm
Width160 mm
Height230 mm
Trip classCLASS 10 A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

Motor starting in hazardous zones — ATEX, UKEX, IECEx certified

The 3RW5073-2AB14: This soft starter carries ATEX, UKEX, and IECEx certification, enabling direct installation in Zone 1 or Zone 2 motor control centers without an additional isolation barrier between the starter and the hazardous atmosphere. The 200-480 V rated voltage covers the common low-voltage motor networks across 50 Hz and 60 Hz regions, with the control supply accepting 110-250 V at both frequencies.

Trip Class selection and thermal coordination

The 100 A minimum load rating sets the floor for motor FLA matching; below this the internal current sensing may not trigger reliable overload protection, so pair it with a motor whose full-load amps sit at or above 100 A.

Fieldbus integration and analog feedback

The analog output defaults to 4-20 mA and can be parameterized to 0-10 V via the High Feature HMI, feeding motor current or torque back to the control system for process monitoring. PROFIenergy support allows coordinated energy-saving pauses during production idle times when paired with a PROFINET communication module.

Mounting clearances and enclosure fit

Screw fixing to the backplate — no DIN rail adapter — so the panel layout must allow for the 160 mm width, 230 mm height, and 282 mm depth with the following minimum clearances: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind the mounting surface. The 15 g / 11 ms shock resistance rating means it holds calibration under vibration from nearby contactors or mobile equipment, but above 12 g / 11 ms potential contact lifting may occur — bolt the mounting screws to torque spec.

Active production — sourcing posture

UL and CSA approvals are listed, so the part qualifies for North American panel builds without a separate evaluation file.

MPN
3RW5073-2AB14