Siemens 3RW5073-2TB05 — Soft Starters

Siemens 3RW5073-2TB05 Soft Starter, 100 A min, ATEX

MPN3RW5073-2TB05
Active

Siemens 3RW5073-2TB05 soft starter, 100 A minimum operating current, 200–600 V control supply, ATEX and IECEx certified, trip class 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP/PROFINET, UL/CSA/CE.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5073-2TB05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5073-2TB05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)132 kW
Rated motor power at 230 V (40 °C)75 kW
Rated operational current at 40 °C250 A
Rated operational current at 50 °C220 A
Rated operational current at 60 °C200 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)2 043 W
3RW5073-2TB05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5073-2TB05 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5073-2TB05 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5073-2TB05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5073-2TB05 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5073-2TB05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Hazardous-area motor starting with ATEX certification

The 3RW5073-2TB05 is a Siemens soft starter carrying ATEX and IECEx certification, meaning it is approved for installation in explosive atmospheres where gas or dust hazards are present. This is the primary differentiator from standard soft starters — the ATEX marking and IECEx marking allow direct integration into Zone 1/21 or Zone 2/22 motor control circuits without additional enclosure isolation. Rated for a minimum operating current of 100 A with a control supply voltage range of 200–600 V, this unit covers global line voltages from 208 V to 600 V without a transformer tap change. The wide input window simplifies BOM planning for multi-voltage sites.

Trip class and overload protection for motor heating

The trip class is configurable as CLASS 10A, 10E, or 20E per IEC 60947-4-2. The preset is 10E, which matches most pump and fan applications. The minimum load setting is 15 % of the smallest settable Ie, which means the starter can be tuned down to protect lightly loaded motors without nuisance tripping. This is relevant when the motor FLA is near the lower end of the 100 A minimum.

Fieldbus integration and communication options

The 3RW5073-2TB05 supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET with PROFIenergy. This multi-protocol capability means the same hardware can be commissioned on a Rockwell ControlLogix network (EtherNet/IP) or a Siemens S7-1500 (PROFINET) without a gateway. The PROFIenergy profile allows the starter to pause loads during production breaks, saving energy at the panel level. Remote reset is achieved by cycling the 24 V DC control supply off and on. The error logbook is available only with special accessories — if fault logging is required for your maintenance plan, factor in the additional module at the BOM stage.

Mounting dimensions and panel integration

The unit measures 160 mm wide × 230 mm high × 282 mm deep and is fastened via screw fixing. The mounting position allows vertical surface mounting with ±90° rotation and ±22.5° tilt forward/backward — this gives flexibility in tight enclosures but requires the derating curve to be checked if the unit is not vertically oriented. Clearance requirements: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, and 5 mm at the sides. The zero backward clearance means the unit can be mounted flush against the back panel, saving depth in shallow enclosures.

Operating temperature and derating

In a non-air-conditioned panel in a Middle East or Southeast Asian plant, the internal temperature can exceed 50 °C — the derating curve must be applied to the continuous current rating to avoid thermal overload trips during normal running. Shock resistance is rated at 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms. For installations on vibrating machinery (compressors, large conveyors), the mounting bracket should be isolated or the shock spec verified against the machine's vibration profile.

Compliance and approvals for global installations

The 3RW5073-2TB05 carries UL approval, CSA approval, and CE marking. For a panel destined for a US chemical plant with ATEX-rated equipment, this single starter satisfies both NEC and IECEx requirements without a separate enclosure.

Sourcing and lifecycle — active production

For a line-down spare or a new project BOM, this part is sourced through authorized distribution channels and quoted to order against the RFQ quantity.

Frequently asked questions

What ATEX certification does 3RW5073-2TB05 carry?

The 3RW5073-2TB05 is ATEX certified and also carries IECEx certification. This qualifies it for installation in explosive atmospheres (gas and dust) without requiring additional enclosure isolation, per the ATEX 2014/34/EU directive.

What is the minimum operating current for 3RW5073-2TB05?

The minimum operating current is 100 A. This sets the lower bound for motor full-load amps — the starter cannot be adjusted below this value. For motors with FLA below 100 A, a smaller frame soft starter would be required.

What fieldbus protocols does 3RW5073-2TB05 support?

It supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET with PROFIenergy. This covers the major industrial Ethernet and fieldbus networks without additional gateways.

MPN
3RW5073-2TB05