Skip to main content
Siemens 3RW5073-6TB14 — Soft Starters

Siemens 3RW5073-6TB14 Soft Starter, 100 A, 200-480 V, ATEX

MPN3RW5073-6TB14
Active

Siemens SIRIUS 3RW5073-6TB14 soft starter, 100 A minimum, 200-480 V, ATEX/UKEX/IECEx, Trip Class 10A/10E/20E, screw fixing, 160 x 230 x 282 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RW5073-6TB14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5073-6TB14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)132 kW
Rated motor power at 230 V (40 °C)75 kW
Rated operational current at 40 °C250 A
Rated operational current at 50 °C220 A
Rated operational current at 60 °C200 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)2 043 W
3RW5073-6TB14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5073-6TB14 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5073-6TB14 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5073-6TB14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5073-6TB14 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5073-6TB14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Integrator's brief

The 3RW5073-6TB14: Trip Class is selectable between CLASS 10A, 10E (preset), and 20E per IEC 60947-4-2. CLASS 10A provides the fastest overload protection for standard induction motors; 20E allows longer starting times for high-inertia loads like centrifuges or crushers. The preset 10E is a common middle ground for general-purpose pumping and conveying.

Fastening is by screw fixing; the footprint is 160 mm wide, 230 mm high, and 282 mm deep. Clearance requirements: 100 mm upwards, 75 mm downwards, 10 mm forwards, 0 mm backwards, and 5 mm at the side. These are the minimum free-air gaps for heat dissipation — panel builders should account for them in the enclosure layout to avoid derating above 40 °C ambient. The unit carries a service factor of 1, so no continuous overload margin is built in — sizing must match the motor full-load amps exactly.

Control and communications

Fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. PROFIenergy is supported when used with the PROFINET Standard communication module, enabling energy-saving pauses during idle periods on automated lines. Remote reset is achieved by cycling the control supply voltage. Soft Torque and Voltage Ramp starting modes are available, along with Pump Ramp Down for controlled deceleration of centrifugal loads — useful for preventing water hammer in pumping stations. There is no analog output and no torque control; the unit is a basic ramp-start soft starter, not a closed-loop controller. The minimum load is 15% of the smallest settable Ie, so it can handle lightly loaded motors without nuisance tripping. An error logbook is available only with special accessories. Auto-reset is supported.

CE, UL, and CSA approvals are listed, covering European, US, and Canadian installations. ATEX, UKEX, and IECEx certifications are present — this is the version for explosive-environment motor control. The lifecycle stage is current, meaning Siemens continues to manufacture and support this order code without an announced end-of-life.

Frequently asked questions

What is the rated current for the Siemens 3RW5073-6TB14 soft starter?

The minimum rated operating current is 100 A. The unit is designed for motors drawing at least that much full-load current at the rated voltage of 200 to 480 V.

What are the ATEX and UKEX certifications on this soft starter?

The 3RW5073-6TB14 carries ATEX, UKEX, and IECEx certifications, allowing installation in potentially explosive atmospheres when controlling Ex-rated motors.

MPN
3RW5073-6TB14