Siemens 3RW5074-2AB04 Soft Starter, 135 A Min, 200-480 V

MPN3RW5074-2AB04
Active

Siemens 3RW5074-2AB04 SIRIUS soft starter, 135 A minimum current, 200-480 V rated voltage, ATEX/UKEX/IECEx approved, trip class 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP/PROFINET, 160x230x282 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5074-2AB04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5074-2AB04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)160 kW
Rated motor power at 230 V (40 °C)90 kW
Rated operational current at 40 °C315 A
Rated operational current at 50 °C279 A
Rated operational current at 60 °C255 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)2 805 W
3RW5074-2AB04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5074-2AB04 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5074-2AB04 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5074-2AB04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5074-2AB04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5074-2AB04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Motor starting in hazardous zones — ATEX-rated soft starter

The 3RW5074-2AB04: Trip class is configurable to CLASS 10A, 10E (preset), or 20E per IEC 60947-4-2 — select 10A for standard-start loads like pumps, or 20E for high-inertia loads that need longer acceleration time without nuisance tripping. Soft torque, voltage ramp, and pump ramp down features reduce mechanical shock on startup and prevent water hammer on pump stop — these are the settings that protect the driven load, not just the motor.

Fieldbus and analog feedback — integration checklist

Supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard — the 3RW5074-2AB04 can drop into most industrial networks without a protocol gateway. Analog output provides 4-20 mA (default) or 0-10 V feedback — parameterizable via High Feature HMI — for motor current or load monitoring back to the PLC. Auto-reset and remote reset (by cycling control supply voltage) allow the starter to recover from overload trips without a technician hitting the panel — useful in remote or automated lines.

Panel fit and mounting constraints

Dimensions are 160 mm width, 230 mm height, 282 mm depth — screw fixing (not DIN-rail snap-on) so budget for four mounting holes and a 300 mm deep enclosure. Mounting position allows vertical surface with +/-90° rotation and +/-22.5° tilt forward/backward — the clearance requirements are 100 mm upwards, 75 mm downwards, 10 mm forwards, 0 mm backwards, and 5 mm at the side.

Carries CE marking, UL approval, and CSA approval — covers European and North American regulatory acceptance. ATEX, UKEX, and IECEx extend coverage to hazardous-area installations.

Frequently asked questions

What ATEX/UKEX/IECEx approvals does the 3RW5074-2AB04 carry?

The 3RW5074-2AB04 is approved for ATEX, UKEX, and IECEx, enabling use in explosive atmospheres (hazardous-area motor control). It also carries CE, UL, and CSA marks.

MPN
3RW5074-2AB04