Siemens 3RW5075-2AB04 — Soft Starters

Siemens 3RW5075-2AB04 Soft Starter, 160 A, 200-480 V, ATEX

MPN3RW5075-2AB04
Active

Siemens 3RW5075-2AB04 soft starter, 160 A minimum rated current, 200-480 V operating range, ATEX/UKEX/IECEx certified, trip class 10A/10E/20E, screw fixing, 282 x 160 x 230 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5075-2AB04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5075-2AB04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)200 kW
Rated motor power at 230 V (40 °C)110 kW
Rated operational current at 40 °C370 A
Rated operational current at 50 °C328 A
Rated operational current at 60 °C300 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)3 124 W
3RW5075-2AB04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5075-2AB04 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5075-2AB04 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5075-2AB04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5075-2AB04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5075-2AB04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

160 A soft starter with ATEX certification for hazardous zones

The Siemens 3RW5075-2AB04 is a hybrid switching device rated for a minimum of 160 A, operating across 200-480 V. It carries ATEX, UKEX, and IECEx certification, meaning it can be installed in explosive atmospheres (gas or dust) without an additional isolation barrier — the soft starter itself is the Ex-rated component. Trip class is selectable between CLASS 10A, 10E (preset), or 20E per IEC 60947-4-2. The unit measures 282 mm deep, 160 mm wide, and 230 mm high, with screw fixing to the mounting surface. Mounting position is flexible — vertical surface with ±90° rotation and ±22.5° tilt front-to-back — which helps when retrofitting into existing enclosures where the old starter's footprint doesn't match.

Fieldbus and control integration

Communication options cover PROFIBUS, PROFINET (with PROFIenergy support via the standard communication module), Modbus RTU, Modbus TCP, and EtherNet/IP. This makes the 3RW5075-2AB04 a drop-in for most plant-floor networks without a protocol gateway — the soft starter speaks the line's native fieldbus. An analog output is configurable as 4-20 mA (default) or 0-10 V (parameterizable with the High Feature HMI). This gives the PLC or DCS a direct current or voltage signal proportional to motor current, useful for trending load changes on pumps or conveyors without a separate CT. Auto-reset and remote reset (by cycling the control supply voltage) are both supported, reducing the need for a manual reset button at the panel when the starter trips on overload. The error logbook feature is available only with special accessories.

Starting profiles for mechanical and electrical stress reduction

Voltage ramp and soft torque are both available. Voltage ramp gradually increases motor voltage over an adjustable period, limiting inrush current to typically 300-400% of FLA instead of the 600-800% seen with direct-on-line starts. Soft torque further shapes the initial torque ramp to reduce mechanical shock on gearboxes and belt drives. Pump ramp down is included — a controlled deceleration profile that reduces the motor voltage gradually during stop, minimising fluid hammer in piping systems. This is a standard feature, not an option card. Minimum load is 15% relative to the smallest settable Ie, meaning the soft starter can handle lightly loaded motors without dropping out of regulation. The service factor is 1, so continuous operation at rated current is the design limit — no built-in overload margin.

Environmental and compliance documentation

The unit withstands 15 g / 11 ms shock (12 g / 11 ms with potential contact lifting). Clearance distances: 100 mm upwards, 10 mm forwards, 75 mm downwards, 5 mm at the sides. ATEX, UKEX, and IECEx certification means the unit is suitable for Zone 1/21 or Zone 2/22 hazardous areas per the applicable equipment group — the exact zone classification depends on the gas/dust group and temperature class of the installation.

For panel builders or MRO buyers: the screw-fixing mount and flexible orientation mean it can replace an older soft starter in the same enclosure without drilling new holes, provided the 282×160×230 mm envelope fits. Confirm the control voltage and fieldbus protocol match your existing network before committing the BOM line.

Frequently asked questions

What ATEX certification does the 3RW5075-2AB04 carry?

The 3RW5075-2AB04 is ATEX certified (Yes), along with UKEX and IECEx certification. This covers installation in explosive atmospheres per the applicable equipment group — the unit itself is the Ex-rated component, so no additional isolation barrier is required in Zone 1/21 or Zone 2/22 areas.

What trip classes are available on the 3RW5075-2AB04?

Trip class is selectable between CLASS 10A, 10E (preset), or 20E per IEC 60947-4-2. CLASS 10E provides a 10-second thermal overload protection window at 7.2× rated current; CLASS 20E extends that to 20 seconds for high-inertia loads.

How do I check stock and pricing for the 3RW5075-2AB04?

Submit a request through the storefront; the sourcing team will provide a quote with lead time and volume pricing from authorized Siemens distribution.

MPN
3RW5075-2AB04