Siemens 3RW5075-6AB15

Siemens 3RW5075-6AB15 Soft Starter, 160 A, 200-600 V, ATEX

MPN 3RW5075-6AB15
Active

Siemens 3RW5075-6AB15 soft starter, 160 A minimum rated current, 200-600 V operating voltage, ATEX/UKEX/IECEx certified, trip class 10A/10E/20E per IEC 60947-4-2, screw fixing, 282 mm depth.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5075-6AB15 specifications
ParameterValue
Mountingscrew fixing
Depth282 mm
Width160 mm
Height230 mm
Trip classCLASS 10 A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

What this soft starter carries for hazardous-area and motor protection

The 3RW5075-6AB15 is a Siemens hybrid soft starter rated for a minimum operating current of 160 A across a voltage range of 200 to 600 V. It carries ATEX, UKEX, and IECEx certification, so it's suited for motor starting in potentially explosive atmospheres — not just standard industrial panels. Trip class is configurable between CLASS 10A, 10E (preset), and 20E per IEC 60947-4-2.

Fieldbus integration and soft-start features

On the communications side, this soft starter supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. That covers most common control networks without needing a separate gateway — a straight drop into a Siemens S7 or Rockwell ControlLogix rack. Soft-start functions include voltage ramp, soft torque, and pump ramp down. The pump ramp down is specifically for preventing water hammer in pump applications — it gradually reduces voltage rather than coasting to a stop. The analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI parameterization. That gives a direct motor current or voltage feedback signal back to a PLC analog input without an external transducer.

Installation clearances and environmental limits

Mounting is screw fixing, with specified clearances: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the side, and 0 mm backwards. Those gaps matter for airflow and arc flash containment — the 100 mm above is the critical one for hot exhaust. If the panel ambient sits at 50 °C, you'll need to reduce the continuous current rating — the derating curve in the manual is the guide. Shock resistance is 15 g for 11 ms, dropping to 12 g / 11 ms with potential contact lifting.

No stock-holding claim — this is a build-to-order or quote-to-order item for most distributors.

MPN
3RW5075-6AB15