Siemens 3RW5075-6AB15 — Soft Starters

Siemens 3RW5075-6AB15 Soft Starter, 160 A, 200-600 V, ATEX

MPN3RW5075-6AB15
Active

Siemens 3RW5075-6AB15 soft starter, 160 A minimum rated current, 200-600 V operating voltage, ATEX/UKEX/IECEx certified, trip class 10A/10E/20E per IEC 60947-4-2, screw fixing, 282 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5075-6AB15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5075-6AB15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)200 kW
Rated motor power at 230 V (40 °C)110 kW
Rated operational current at 40 °C370 A
Rated operational current at 50 °C328 A
Rated operational current at 60 °C300 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)3 124 W
3RW5075-6AB15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5075-6AB15 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5075-6AB15 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5075-6AB15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5075-6AB15 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5075-6AB15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

What this soft starter carries for hazardous-area and motor protection

The 3RW5075-6AB15 is a Siemens hybrid soft starter rated for a minimum operating current of 160 A across a voltage range of 200 to 600 V. It carries ATEX, UKEX, and IECEx certification, so it's suited for motor starting in potentially explosive atmospheres — not just standard industrial panels. Trip class is configurable between CLASS 10A, 10E (preset), and 20E per IEC 60947-4-2.

Fieldbus integration and soft-start features

On the communications side, this soft starter supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. That covers most common control networks without needing a separate gateway — a straight drop into a Siemens S7 or Rockwell ControlLogix rack. Soft-start functions include voltage ramp, soft torque, and pump ramp down. The pump ramp down is specifically for preventing water hammer in pump applications — it gradually reduces voltage rather than coasting to a stop. The analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI parameterization. That gives a direct motor current or voltage feedback signal back to a PLC analog input without an external transducer.

Installation clearances and environmental limits

Mounting is screw fixing, with specified clearances: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the side, and 0 mm backwards. Those gaps matter for airflow and arc flash containment — the 100 mm above is the critical one for hot exhaust. If the panel ambient sits at 50 °C, you'll need to reduce the continuous current rating — the derating curve in the manual is the guide. Shock resistance is 15 g for 11 ms, dropping to 12 g / 11 ms with potential contact lifting.

No stock-holding claim — this is a build-to-order or quote-to-order item for most distributors.

Frequently asked questions

What approvals does 3RW5075-6AB15 carry for hazardous-area use?

It carries ATEX, UKEX, and IECEx certification, plus UL and CSA approval and CE marking. That covers installation in Zone 1/21 hazardous areas and North American Class I Division 2 locations.

MPN
3RW5075-6AB15