Siemens 3RW5076-2AB04 — Soft Starters

3RW5076-2AB04 Soft Starter, 200 A, 200-480 V, ATEX, Active

MPN3RW5076-2AB04
Active

Siemens 3RW5076-2AB04 soft starter, 200 A rated current, 200-480 V supply, ATEX/UKEX/IECEx certified, Trip Class 10A/10E/20E, active production.

$1,987.55Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5076-2AB04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5076-2AB04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)250 kW
Rated motor power at 230 V (40 °C)132 kW
Rated operational current at 40 °C470 A
Rated operational current at 50 °C416 A
Rated operational current at 60 °C380 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 438 W
3RW5076-2AB04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5076-2AB04 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5076-2AB04 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5076-2AB04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5076-2AB04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5076-2AB04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

200 A soft starter with ATEX — motor starting in hazardous zones

The 3RW5076-2AB04 is a hybrid soft starter rated 200 A minimum operating current, covering motor loads from 200 A up to the device's full rating within a 200-480 V supply range. ATEX, UKEX, and IECEx certifications qualify this unit for installation in explosive atmospheres — a requirement for chemical, oil/gas, and grain handling lines where standard soft starters cannot go. Trip Class is configurable as CLASS 10A, 10E (preset), or 20E per IEC 60947-4-2, letting you match the overload protection to the motor start profile — 10A for short starts, 20E for longer acceleration times on high-inertia loads. Fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET, so it drops into most control networks without a gateway.

Mounting and panel fit — screw-fix, 282x160x230 mm

Mounting is screw-fix only — no DIN-rail clip, so plan for a dedicated backplate or sub-panel. Dimensions are 282 mm deep, 160 mm wide, 230 mm high. The mounting position allows vertical surface with ±90° rotation and ±22.5° tilt front-to-back, giving some flexibility for tight enclosures but not a free orientation. Clearance requirements: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, 5 mm at the side — factor these into the panel layout for airflow and cable entry.

No stock-holding claim — quoted per order. UL, CSA, and CE markings are on file, covering North American and European regulatory acceptance without additional certification steps.

Frequently asked questions

Where can I buy 3RW5076-2AB04 and how do I get a price?

No stock-holding claim is made here.

What ATEX and UKEX certifications does 3RW5076-2AB04 carry?

ATEX, UKEX, and IECEx are all listed as 'Yes', meaning the unit is certified for use in explosive atmospheres per those standards. This is a key differentiator from standard soft starters.