Skip to main content
Siemens 3RW5076-2AB05 — Soft Starters

Siemens 3RW5076-2AB05 Soft Starter, 200A

MPN3RW5076-2AB05
Active

Siemens SIRIUS 3RW5076-2AB05 soft starter, 200 A minimum, trip class 10A / 10E / 20E, 200-600 V, ATEX, UL, CSA, CE, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5076-2AB05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5076-2AB05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)250 kW
Rated motor power at 230 V (40 °C)132 kW
Rated operational current at 40 °C470 A
Rated operational current at 50 °C416 A
Rated operational current at 60 °C380 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 438 W
3RW5076-2AB05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5076-2AB05 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5076-2AB05 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5076-2AB05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5076-2AB05 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5076-2AB05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

The Siemens 3RW5076-2AB05 is a SIRIUS soft starter rated for a minimum motor current of 200 A, with trip class selectable between CLASS 10A, 10E, or 20E per IEC 60947-4-2. That trip class range means you can match the overload protection to the start profile: CLASS 10A for standard starts, CLASS 10E for slightly extended acceleration, or CLASS 20E for high-inertia loads like fans or centrifuges where the start current takes longer to decay. The rated operating voltage spans 200 to 600 V AC, covering common low-voltage three-phase supplies across global installations. This unit carries ATEX and IECEx certification, approved for use in potentially explosive atmospheres. UL, CSA, and CE markings are present.

Fieldbus and control integration

The 3RW5076-2AB05 supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET, giving you broad fieldbus flexibility to drop it into most common industrial networks without a gateway. PROFIenergy is available in connection with the PROFINET standard communication module, useful for energy management during idle phases. An analog output is present, configurable as 4-20 mA or 0-10 V, which can feed motor current or load status to a PLC or HMI. Remote reset is accomplished by cycling the control supply voltage off then on — no separate reset signal wire needed. Auto-reset is also supported, which can be used for unattended restart after a fault clears, though you'll want to evaluate that against your safety circuit design.

Mounting is by screw fixing, not DIN rail. The unit measures 160 mm wide, 230 mm high, and 282 mm deep, so it needs a dedicated backplate or sub-panel — plan for that footprint plus the specified clearance: 100 mm upwards, 75 mm downwards, 10 mm forwards, 0 mm backwards, and 5 mm at the sides. Shock resistance is 15 g / 11 ms, with potential contact lifting starting at 12 g / 11 ms, meaning it can handle moderate vibration but not heavy repetitive shock without consideration.

Frequently asked questions

Does 3RW5076-2AB05 support PROFIBUS or Modbus?

Yes, the 3RW5076-2AB05 supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET, giving you broad fieldbus flexibility.

What is the trip class of 3RW5076-2AB05?

The trip class is selectable as CLASS 10A, 10E, or 20E per IEC 60947-4-2, allowing you to match overload protection to the motor start profile.

Where can I buy 3RW5076-2AB05?

This part is sourced to order; availability and pricing are confirmed at quote time.

MPN
3RW5076-2AB05