Siemens 3RW5076-2AB14 Soft Starter, 200 A, 200-480 V, ATEX

MPN3RW5076-2AB14
Active

Siemens 3RW5076-2AB14 SIRIUS soft starter, 200 A minimum, 200-480 V rated, ATEX/UKEX/IECEx certified, Class 10A/10E/20E trip, screw fixing, 160x230x282 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5076-2AB14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5076-2AB14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)250 kW
Rated motor power at 230 V (40 °C)132 kW
Rated operational current at 40 °C470 A
Rated operational current at 50 °C416 A
Rated operational current at 60 °C380 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 438 W
3RW5076-2AB14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5076-2AB14 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5076-2AB14 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5076-2AB14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5076-2AB14 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5076-2AB14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

200 A soft starter for ATEX zones and motor control panels

The Siemens 3RW5076-2AB14 is a SIRIUS hybrid soft starter rated for a minimum operating current of 200 A across a 200-480 V supply range. It carries ATEX, UKEX, and IECEx certification, meaning it's approved for installation in explosive atmospheres — a requirement you don't see on every soft starter in this class.

Trip class, fieldbus, and environmental fit

Trip class is selectable between CLASS 10A, 10E (preset), and 20E per IEC 60947-4-2. Fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP — the Modbus TCP and EtherNet/IP ports let it talk directly to a PLC without a gateway module, saving a DIN-rail slot and a configuration step. In a Gulf Coast panel that hits 50 °C inside the enclosure during summer, you'll need to account for that derating in the motor full-load current match.

Mounting and approvals for panel integration

Fastening method is screw fixing — not DIN-rail snap-on, so budget for a backplate or mounting bracket. Dimensions are 160 mm wide, 230 mm high, 282 mm deep, which fits a standard 600 mm deep enclosure with room for cabling at the rear. Clearance requirements: 100 mm upward, 10 mm forward, 75 mm downward, 5 mm at the side, 0 mm backward. The zero backward clearance means it can sit flush against the backplane — useful when you're packing multiple starters into a tight MCC section. UL and CSA approvals are both listed, so it's accepted in North American panels without a separate evaluation. CE marking is present for European installations.

Frequently asked questions

What ATEX and UKEX certifications does the 3RW5076-2AB14 carry?

The unit is certified ATEX, UKEX, and IECEx. These approvals qualify it for installation in explosive atmospheres — zones where flammable gases, vapors, or dusts may be present — without needing additional enclosure protection for the starter itself.

MPN
3RW5076-2AB14