Siemens 3RW5076-2TB14 Soft Starter, 200-480 V, 200 A, ATEX

MPN3RW5076-2TB14
Active

Siemens 3RW5076-2TB14 soft starter, 200-480 V rated, 200 A minimum setting, ATEX/UKEX/IECEx approved, trip class 10A/10E/20E per IEC 60947-4-2, screw fixing, 282 x 160 x 230 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5076-2TB14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5076-2TB14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)250 kW
Rated motor power at 230 V (40 °C)132 kW
Rated operational current at 40 °C470 A
Rated operational current at 50 °C416 A
Rated operational current at 60 °C380 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 438 W
3RW5076-2TB14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5076-2TB14 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5076-2TB14 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5076-2TB14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5076-2TB14 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5076-2TB14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Soft starter for motor starting in hazardous areas

The Siemens 3RW5076-2TB14 is a soft starter rated for 200-480 V with a minimum setting of 200 A, designed to ramp motors up and down smoothly while limiting inrush current. It carries ATEX, UKEX, and IECEx approvals, meaning it can be installed in explosive atmospheres where a standard starter would be a fire risk — the enclosure and internal arcing protection meet the zone requirements. Trip class is configurable between CLASS 10A, 10E (preset), and 20E per IEC 60947-4-2, so you match the overload protection to the motor's thermal capacity — 10A for standard motors, 20E for high-inertia loads like centrifuges.

Fieldbus integration and starting profiles

Supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP — the soft starter talks directly to the PLC without a separate gateway, saving a slot in the control cabinet. Starting profiles include soft torque, voltage ramp, and pump ramp down — the pump ramp down feature prevents water hammer on discharge lines by extending the deceleration time. Auto-reset and remote reset (by cycling the control supply voltage) let the starter recover from a fault without a site visit, which matters for remote pumping stations or conveyor lines.

Mounting and environmental limits

Mounts via screw fixing — no DIN-rail clip, so plan for a backplate or panel with drilled holes. Dimensions are 282 mm deep, 160 mm wide, 230 mm high; allow 100 mm clearance above and 75 mm below for airflow. Shock resistance is 15 g / 11 ms — it survives the bump of a nearby press or crusher without the contacts lifting.

CE marked for the European market, UL and CSA approved for North America — the documentation package covers RoHS and REACH compliance as standard for Siemens industrial controls.

Frequently asked questions

What ATEX and UKEX approvals does the 3RW5076-2TB14 carry?

It is listed with ATEX, UKEX, and IECEx approvals — suitable for installation in explosive atmospheres per the respective directives.

MPN
3RW5076-2TB14