Siemens 3RW5077-2AB15 — Soft Starters

Siemens 3RW5077-2AB15 Soft Starter, 240 A Min, ATEX, IECEx

MPN3RW5077-2AB15
Active

Siemens SIRIUS 3RW5077-2AB15 soft starter, 240 A minimum setting, 200-600 V rated, Class 10A/10E/20E, ATEX, IECEx, UL, CSA, CE, PROFIBUS/Modbus/EtherNet/IP.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5077-2AB15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5077-2AB15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)315 kW
Rated motor power at 230 V (40 °C)160 kW
Rated operational current at 40 °C570 A
Rated operational current at 50 °C504 A
Rated operational current at 60 °C460 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)5 801 W

Control & Connection

3RW5077-2AB15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %

Protection & Features

3RW5077-2AB15 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5077-2AB15 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5077-2AB15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5077-2AB15 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s

Electrical

3RW5077-2AB15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

240 A minimum setting, Class 10A/10E/20E trip

The 3RW5077-2AB15: That covers standard global low-voltage networks without a transformer swap between regions.

ATEX, IECEx, and fieldbus options

ATEX and IECEx certified — this unit is listed for explosive-atmosphere installations, so it can sit in Zone 2 or Zone 22 motor starter panels without an additional isolation barrier. UL and CSA approvals plus CE marking round out the compliance set for North American and European markets. Fieldbus integration is built in: PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP are all supported. PROFIenergy is available when paired with the PROFINET communication module — useful for energy management in automated lines.

Mounting and environment — screw fixing, 282 mm depth

Mounting is by screw fixing with a vertical mounting surface, rotatable ±90° and tiltable ±22.5° front-to-back. Dimensions: 160 mm wide, 230 mm high, 282 mm deep. The 282 mm depth is the key panel clearance number — standard 300 mm deep enclosures fit it with 18 mm to spare for wiring ducts. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if potential contact lifting is a concern. Clearances: 100 mm upwards, 10 mm forwards, 75 mm downwards, 5 mm sideways — plan the enclosure layout accordingly.

Lifecycle status is current production. This is not a legacy or phase-out line — the 3RW5077-2AB15 is an active catalog item from Siemens.

Frequently asked questions

What are the key approvals for the 3RW5077-2AB15?

It carries ATEX, IECEx, UL, CSA, and CE marking. These cover explosive atmospheres, North American electrical codes, and European CE-mark compliance.