Siemens 3RW5077-2TB14 — Soft Starters

Siemens 3RW5077-2TB14 Soft Starter, 240 A, 200-480 V, ATEX

MPN3RW5077-2TB14
Active

Siemens SIRIUS 3RW5077-2TB14 soft starter, 200-480 V, 240 A minimum, ATEX/IECEx, trip class 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP, screw fixing, 160x230x282 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5077-2TB14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5077-2TB14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)315 kW
Rated motor power at 230 V (40 °C)160 kW
Rated operational current at 40 °C570 A
Rated operational current at 50 °C504 A
Rated operational current at 60 °C460 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)5 801 W

Control & Connection

3RW5077-2TB14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %

Protection & Features

3RW5077-2TB14 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5077-2TB14 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5077-2TB14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5077-2TB14 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s

Electrical

3RW5077-2TB14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Panel fit and mounting constraints

The 3RW5077-2TB14 measures 160 mm wide by 230 mm high by 282 mm deep, screw-fixed to a vertical mounting surface. It can be rotated ±90° or tilted ±22.5° forward/backward, with clearance requirements: 100 mm upward, 75 mm downward, 10 mm forward, 5 mm at the side, and 0 mm backward.

Motor starting profiles and protection

Rated minimum operating current is 240 A across a 200-480 V supply (50/60 Hz). The trip class is selectable between CLASS 10A, 10E (preset), and 20E per IEC 60947-4-2 — CLASS 10A suits standard-start loads; 20E extends the ramp for high-inertia starts without nuisance tripping. Voltage ramp, soft torque, and pump ramp-down profiles are built in. The minimum load setting is 15 % of the smallest settable Ie, which covers light-load applications like unloaded conveyors.

Fieldbus and control integration

Native fieldbus support includes PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. PROFINET with PROFIenergy is available via the standard communication module — useful for coordinated energy management in automated lines. Auto-reset is standard; remote reset is achieved by cycling the control supply voltage (110-250 V at 50/60 Hz). No analog output, no torque control, and no HMI high-feature on this variant.

Compliance and hazardous-area readiness

Carries ATEX and IECEx certification for potentially explosive atmospheres, plus CE, UL, and CSA markings. This covers installations under ATEX 2014/34/EU and IECEx Scheme, as well as North American NEC/CEC — one part number for global hazardous-area motor starting. Shock resistance rated 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms. Service factor is 1.0 — no overload margin beyond nameplate.

Frequently asked questions

What ATEX and IECEx certifications does this soft starter carry?

ATEX and IECEx certified for use in potentially explosive atmospheres, alongside CE, UL, and CSA approvals.

What trip classes are available on 3RW5077-2TB14?

Trip class is selectable among CLASS 10A, CLASS 10E (preset), and CLASS 20E, per IEC 60947-4-2.

MPN
3RW5077-2TB14