Siemens 3RW5077-6AB05 — Soft Starters

Siemens 3RW5077-6AB05 Soft Starter, 240 A, 200-600 V, ATEX

MPN3RW5077-6AB05
Active

Siemens 3RW5077-6AB05 soft starter, 240 A minimum, 200-600 V rated voltage, ATEX, IECEx, UL, CSA, CE, PROFIBUS, PROFINET, Modbus RTU/TCP, EtherNet/IP, 282 mm depth, 160 mm width, 230 mm height.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5077-6AB05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5077-6AB05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)315 kW
Rated motor power at 230 V (40 °C)160 kW
Rated operational current at 40 °C570 A
Rated operational current at 50 °C504 A
Rated operational current at 60 °C460 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)5 801 W

Control & Connection

3RW5077-6AB05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %

Protection & Features

3RW5077-6AB05 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5077-6AB05 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5077-6AB05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5077-6AB05 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s

Electrical

3RW5077-6AB05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Rated current and voltage envelope

The 3RW5077-6AB05 is a Siemens SIRIUS soft starter rated for a minimum operating current of 240 A across a 200-600 V supply range. The trip class is configurable as CLASS 10A, 10E (preset), or 20E per IEC 60947-4-2.

Hazardous-area and global approvals

ATEX and IECEx certification are listed on this variant — the soft starter may be installed in Zone 2 or Zone 22 gas/dust atmospheres, per the equipment group and temperature class on the nameplate. This is a distinguishing feature: not all 3RW5 frame sizes carry ATEX, so the -6AB05 suffix confirms the hazardous-area rating. UL, CSA, and CE marking are all present, covering North American and European installation codes. For a tender submission or panel build destined for a CE-marked machine, the CE declaration of conformity is available from Siemens per the standard documentation package.

Fieldbus and control interface

The base unit supports PROFIBUS, PROFINET (standard), Modbus RTU, Modbus TCP, and EtherNet/IP — all listed as native, not requiring an external gateway module. This covers the three dominant industrial Ethernet protocols plus the legacy fieldbus, so the starter slots into a Siemens S7-1500 environment or a Rockwell ControlLogix network without a protocol converter. PROFIenergy is supported when paired with the PROFINET communication module, enabling energy-management profiles during idle phases — relevant for pump and fan applications where the motor coasts between cycles. The analog output is configurable as 4-20 mA (default) or 0-10 V, parameterizable via the High Feature HMI. This feeds motor current or power data to a PLC analog input or a local panel meter without a separate transducer.

Mounting and thermal derating

Mounting is screw-fix to a vertical surface, with ±90° rotation and ±22.5° tilt forward/backward allowed. Clearance requirements: 100 mm upward, 75 mm downward, 10 mm forward, 0 mm backward, 5 mm at the sides. The 0 mm backward clearance means the unit can sit flush against the back panel, saving depth in a shallow enclosure. For a panel build in a non-conditioned enclosure, the internal ambient rise must be calculated against the 40 °C threshold — at 50 °C ambient, expect a current derating of approximately 1.5% per °C above 40 °C, though the exact curve is in the Siemens manual. Physical dimensions: 282 mm depth, 160 mm width, 230 mm height. The width fits a standard 160 mm DIN-rail footprint, but note the fastening method is screw-fix, not snap-on — the unit bolts to the mounting plate.

Starting modes and load protection

Voltage ramp and soft torque are both available — voltage ramp is the standard soft-start profile, while soft torque applies a current-limiting ramp that reduces mechanical shock on belt-driven or gear-coupled loads. Pump ramp down is also listed, which extends the deceleration time to prevent water hammer in pump applications. Torque control is not available on this unit — if the application requires closed-loop torque regulation during start (e.g., for tension control), a different SIRIUS variant or a VFD would be needed. Auto-reset and remote reset (by cycling the 24 V DC control supply) are both supported, allowing the starter to re-crank after a fault without a manual panel visit — useful for remote pumping stations.

Lifecycle and sourcing posture

No stock-holding claim is made; the supply posture is per-RFQ confirmation.

Frequently asked questions

What are the ATEX and IECEx ratings on the 3RW5077-6AB05?

Both ATEX and IECEx certification are listed on this soft starter variant. This qualifies the unit for installation in potentially explosive atmospheres (Zone 2 gas, Zone 22 dust), subject to the specific equipment group and temperature class marked on the nameplate.

What fieldbus protocols does the 3RW5077-6AB05 support natively?

The base unit supports PROFIBUS, PROFINET (standard), Modbus RTU, Modbus TCP, and EtherNet/IP. No external gateway module is required for these protocols. PROFIenergy is available when used with the PROFINET communication module.

What is the minimum motor current rating for the 3RW5077-6AB05?

The minimum settable operating current is 240 A. The minimum load is 15% relative to the smallest settable Ie, meaning the starter can handle motors with a full-load current as low as approximately 36 A (15% of 240 A).

MPN
3RW5077-6AB05