Siemens 3RW5124-1XC14 — Soft Starters

Siemens 3RW5124-1XC14 SIRIUS Soft Starter, 200-480 V

MPN3RW5124-1XC14

Siemens SIRIUS 3RW5124-1XC14 soft starter, 200-480 VAC, 20 A minimum, CLASS 10A/10E/20E trip class, PROFIBUS/Modbus RTU/PROFINET, screw terminals, active production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RW5124-1XC14 — Identification
ParameterValue
Product brand nameSIRIUS
3RW5124-1XC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)22 kW
Rated motor power at 230 V (40 °C)11 kW
Rated operational current at 40 °C81.4 A
Rated operational current at 50 °C72 A
Rated operational current at 60 °C62.7 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)522 W
3RW5124-1XC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5124-1XC14 — Protection & Features
ParameterValue
Motor overload protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5124-1XC14 — Mechanical
ParameterValue
Height321 mm
Width185 mm
Depth203 mm
Weight5.2 kg
Mounting position+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5124-1XC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
3RW5124-1XC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Product Feature Integrated Bypass Contact SystemNo
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5124-1XC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 ... 50 %

Product details

What this soft starter does

The Siemens 3RW5124-1XC14 is a SIRIUS soft starter sized for three-phase induction motors on 200-480 VAC supplies. It offers voltage ramp and soft torque starting modes, with a default CLASS 10A trip class per IEC 60947-4-2 — meaning it protects the motor during start-up by allowing a 10-second overload at 7.2x rated current before tripping. You can also set it to CLASS 10E or 20E for heavier starts like crushers or centrifuges. Minimum load is 15% of the smallest settable Ie, so it handles lightly loaded conveyors or pumps without nuisance tripping. The unit supports inside-delta wiring for reduced line current on larger motors.

Fieldbus and control integration

This soft starter ships with PROFIBUS, Modbus RTU, and PROFINET on board — no option card needed. The control circuit uses screw-type terminals. Analog output is 4-20 mA (default) or 0-10 V, parameterizable through the High Feature HMI. Remote reset works by cycling the control supply voltage. Mounting is screw-fix on a vertical surface, with ±10° rotation allowed. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, 0 mm backward. The unit measures 321 mm high by 185 mm wide by 203 mm deep — plan your enclosure gland plate and DIN rail accordingly.

Frequently asked questions

What is the trip class of 3RW5124-1XC14?

Default trip class is CLASS 10A per IEC 60947-4-2, with selectable CLASS 10E and CLASS 20E for heavier starting loads.

MPN
3RW5124-1XC14