Siemens 3RW5126-1XC14-0S — Soft Starters

Siemens 3RW5126-1XC14-0S Soft Starter, 32 A, 200-480 V

MPN3RW5126-1XC14-0S

Siemens 3RW5126-1XC14-0S soft starter, 32 A minimum, 200-480 V, Class 10A/10E/20E, PROFIBUS/Modbus RTU/PROFINET, screw fixing, 321 x 185 x 203 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5126-1XC14-0S — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)37 W
Rated motor power at 230 V (40 °C)22 W
Rated operational current at 40 °C133 A
Rated operational current at 50 °C118 A
Rated operational current at 60 °C107 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)933 W
3RW5126-1XC14-0S — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5126-1XC14-0S — Protection & Features
ParameterValue
Motor overload protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5126-1XC14-0S — Mechanical
ParameterValue
Height321 mm
Width185 mm
Depth203 mm
Weight5.6 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5126-1XC14-0S — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 mm; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5126-1XC14-0S — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC-53b
Product Feature Integrated Bypass Contact SystemNo
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5126-1XC14-0S — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Dimensions and mounting — panel fit

The 3RW5126-1XC14-0S measures 321 mm high, 185 mm wide, and 203 mm deep, secured by screw fixing.

Rated current and voltage — what drives the selection

Minimum operating current is 32 A, with a rated voltage range of 200 to 480 V at 50/60 Hz. The minimum load is 15 % of the smallest settable Ie, so it handles lightly loaded motors without dropping out.

Trip class and starting profile

Trip class is configurable: CLASS 10A (default), 10E, or 20E per IEC 60947-4-2. Starting voltage is adjustable from 30 to 100 %, with a fixed stopping voltage of 50 %. Voltage ramp, soft torque, and ramp-down (soft stop) are all standard — useful for pumps or conveyors where mechanical shock needs limiting.

Fieldbus and control connectivity

Onboard PROFIBUS, Modbus RTU, and PROFINET standard — no extra gateway module needed. The control circuit uses screw-type terminals. Analog output is 4…20 mA (default) or 0…10 V (parameterizable with High Feature HMI). Remote reset is supported by cycling the control supply voltage.

Environmental and derating

Pollution degree 3 per IEC 60947-4-2. Shock resistance is 15 g / 11 ms (12 g / 11 ms with potential contact lifting). Vibration resistance: 15 mm to 6 Hz, 2 g to 500 Hz.

Frequently asked questions

What is 3RW5126-1XC14-0S's listed depth (203 mm) on this Soft Starters line?

The depth is 203 mm. Combined with a height of 321 mm and width of 185 mm, it fits a standard panel with screw fixing and the clearances noted above.

MPN
3RW5126-1XC14-0S