Siemens 3RW5127-1XC14 SIRIUS Soft Starter, 40.5 A, 200-480 V

MPN3RW5127-1XC14

Siemens SIRIUS 3RW5127-1XC14 soft starter, rated 40.5 A minimum at 200-480 V, Trip Class 10A/10E/20E, PROFIBUS/Modbus RTU/PROFINET, screw fixing, 203×185×321 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5127-1XC14 — Identification
ParameterValue
Product brand nameSIRIUS
3RW5127-1XC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)45 W
Rated motor power at 230 V (40 °C)22 W
Rated operational current at 40 °C161 A
Rated operational current at 50 °C143 A
Rated operational current at 60 °C131 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)1 077 W
3RW5127-1XC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5127-1XC14 — Protection & Features
ParameterValue
Motor overload protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5127-1XC14 — Mechanical
ParameterValue
Height321 mm
Width185 mm
Depth203 mm
Weight6.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5127-1XC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 mm; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5127-1XC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC-53b
Product Feature Integrated Bypass Contact SystemNo
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5127-1XC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

What this soft starter covers — motor range and starting profile

The 3RW5127-1XC14: Trip Class defaults to CLASS 10A per IEC 60947-4-2, with selectable 10E and 20E profiles. For a pump or conveyor start that clears in under 10 seconds, the 10A setting holds; for high-inertia loads like a centrifuge that need a longer ramp, switch to 20E to avoid nuisance tripping on the overload curve.

Fieldbus and control wiring — no extra modules needed

PROFIBUS, Modbus RTU, and PROFINET are all onboard — one unit covers the three common industrial fieldbuses without a separate communication module. The control circuit terminates at screw-type terminals, so expect a screwdriver for the signal wiring, not a push-in tool. The analog output defaults to 4-20 mA and can be parameterized to 0-10 V through the High Feature HMI. That single output feeds motor current or power data back to the PLC without a separate transducer.

Mounting and panel clearance — screw-fixed, not DIN-rail

This unit is screw-fixed to the backplate — no DIN-rail latch. Dimensions are 203 mm deep, 185 mm wide, 321 mm tall. Clearance requirements: 100 mm above, 10 mm in front, 75 mm below, 5 mm at the sides, and zero behind. That zero backwards clearance means it can sit flush against the panel rear wall. Mounting position allows vertical surface orientation with ±90° rotation and ±22.5° tilt forward/back. For a panel layout, that gives flexibility to align the HMI display toward the door opening.

Thermal environment and derating — watch the panel ambient

If the panel ambient hits 50 °C, the continuous current rating drops — the datasheet derating curve is the reference for sizing. Shock resistance is 15 g at 11 ms, with potential contact lifting above 12 g. Vibration rating is 15 mm at 6 Hz and 2 g up to 500 Hz. These numbers matter if the soft starter mounts on a machine frame rather than a building floor.

Frequently asked questions

What fieldbus protocols does the 3RW5127-1XC14 support?

PROFIBUS, Modbus RTU, and PROFINET are all integrated onboard — no separate communication module required.

What are the clearance requirements around this soft starter?

Minimum clearances: 100 mm above, 10 mm in front, 75 mm below, 5 mm at the sides, and 0 mm behind — it can sit flush against the back panel.

Can I adjust the starting voltage and stopping behavior?

Starting voltage is adjustable from 30-100%. Stopping voltage is fixed at 50%, non-adjustable. Soft Torque and Voltage Ramp profiles are available for different load types.