Siemens 3RW5134-1XC14-0S — Soft Starters

Siemens 3RW5134-1XC14-0S Soft Starter, 53 A, 200-480 V

MPN3RW5134-1XC14-0S

Siemens 3RW5134-1XC14-0S soft starter, 53 A minimum, 200-480 V, Trip Class 10A, PROFIBUS/Modbus RTU/PROFINET, screw fixing, 324x185x203 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5134-1XC14-0S — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)55 W
Rated motor power at 230 V (40 °C)30 W
Rated operational current at 40 °C196 A
Rated operational current at 50 °C175 A
Rated operational current at 60 °C154 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)1 291 W
3RW5134-1XC14-0S — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5134-1XC14-0S — Protection & Features
ParameterValue
Motor overload protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5134-1XC14-0S — Mechanical
ParameterValue
Height324 mm
Width185 mm
Depth203 mm
Weight6.45 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5134-1XC14-0S — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 mm; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5134-1XC14-0S — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC-53b
Product Feature Integrated Bypass Contact SystemNo
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5134-1XC14-0S — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Trip class and overload protection — what it means for motor starting

The 3RW5134-1XC14-0S is configured with Trip Class 10A as default, with selectable 10E and 20E classes per IEC 60947-4-2. Rated minimum current is 53 A, so this unit is sized for motor loads drawing at least that at full load. The voltage range covers 200 to 480 V, covering common low-voltage industrial supplies across 50/60 Hz systems.

Fieldbus and control — PROFIBUS, Modbus RTU, PROFINET onboard

This soft starter ships with PROFIBUS, Modbus RTU, and PROFINET standard interfaces — no separate communication module needed. That means it drops into a Siemens S7 environment or any Modbus TCP/PROFINET controller without a gateway. The control circuit uses screw-type terminals, and the unit supports voltage ramp start, soft torque, and ramp-down soft stop — giving you adjustable acceleration and deceleration profiles for pumps, conveyors, and fans where mechanical shock matters.

Mounting and clearances — panel fit checklist

Dimensions are 324 mm high, 185 mm wide, 203 mm deep. Mounting is by screw fixing, with the unit positionable on a vertical surface with ±90° rotation and ±22.5° tilt front/back. Required clearances: 100 mm upwards, 10 mm forwards, 75 mm downwards, 5 mm at the sides, and 0 mm backwards — so plan for airflow above and below. Pollution degree 3 per IEC 60947-4-2 means it's rated for industrial environments with conductive dust or occasional condensation.

Frequently asked questions

How do I get pricing and availability for 3RW5134-1XC14-0S?

Submit an RFQ through this listing.

What communication protocols does the 3RW5134-1XC14-0S support?

It supports PROFIBUS, Modbus RTU, and PROFINET standard interfaces onboard, plus an analog output configurable for 4-20 mA or 0-10 V feedback.

What are the mounting clearances required for this soft starter?

Minimum clearances: 100 mm above, 10 mm in front, 75 mm below, 5 mm at the sides, and 0 mm behind.

MPN
3RW5134-1XC14-0S