Siemens 3RW5135-1XC14 — Soft Starters

Siemens 3RW5135-1XC14 SIRIUS Soft Starter, 68 A, 200-480 V

MPN3RW5135-1XC14

Siemens SIRIUS 3RW5135-1XC14 soft starter, 68 A minimum, 200-480 V rated, Trip Class 10A/10E/20E, PROFIBUS/Modbus RTU/PROFINET, screw fixing, 324 x 185 x 203 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5135-1XC14 — Identification
ParameterValue
Product brand nameSIRIUS
3RW5135-1XC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)75 kW
Rated motor power at 230 V (40 °C)37 kW
Rated operational current at 40 °C248 A
Rated operational current at 50 °C222 A
Rated operational current at 60 °C204 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)1 807 W
3RW5135-1XC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5135-1XC14 — Protection & Features
ParameterValue
Motor overload protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3
3RW5135-1XC14 — Mechanical
ParameterValue
Height324 mm
Width185 mm
Depth203 mm
Weight6.45 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5135-1XC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
3RW5135-1XC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Product Feature Integrated Bypass Contact SystemNo
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5135-1XC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 ... 50 %

Product details

The 3RW5135-1XC14 is a SIRIUS soft starter rated for a minimum load current of 68 A across a 200-480 V supply range. That voltage window covers common global line voltages — 208 V, 230 V, 400 V, 460 V — without needing a different tap or module. Trip class is configurable: CLASS 10A (default), 10E, or 20E per IEC 60947-4-2. CLASS 10A clears a stalled rotor in 10 seconds at 7.2× Ie — standard for most pump and fan starts. In a 50 °C panel, expect to reduce the continuous current rating per the manufacturer's curve — plan the thermal budget around the enclosure's internal rise, not the room temperature.

Fieldbus and HMI — integration into an existing control architecture

Onboard fieldbus options include PROFIBUS, Modbus RTU, and PROFINET — no external gateway needed for the three most common industrial Ethernet and serial networks. The integrated HMI offers both Standard and High Feature variants. The High Feature HMI enables parameterization of the analog output — configurable as 4-20 mA (default) or 0-10 V — and supports firmware updates and an error logbook for on-site diagnostics without a laptop. Soft Torque and Voltage Ramp starting modes are selectable, with starting voltage adjustable from 30% to 100% and stopping voltage fixed at 50%. This lets you tune the acceleration profile to the load — a conveyor needs a soft ramp, a compressor can take a faster voltage ramp.

Panel mounting and clearances — fitting into an existing enclosure

Mounting is by screw fixing — no DIN rail clip. Overall dimensions are 324 mm height, 185 mm width, 203 mm depth. The depth is the critical dimension for shallow enclosures; at 203 mm it fits most standard 300 mm deep cabinets with room for the wiring duct. Required clearances around the unit: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, and 5 mm at the sides. The zero rear clearance means it can sit flush against the back panel — useful when retrofitting into a crowded enclosure.

The control circuit uses screw-type terminals — standard for panel wiring, no special tooling needed. Inside-delta circuit connection is supported, which reduces the soft starter current rating requirement by 58% compared to in-line connection — useful when upsizing the motor but keeping the same soft starter frame.

Frequently asked questions

What is 3RW5135-1XC14's trip class and what does it mean for my motor?

The trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2. CLASS 10A clears a stalled rotor in 10 seconds at 7.2× Ie — suitable for standard pump and fan starts. CLASS 20E allows up to 20 seconds for high-inertia loads like centrifuges.

What fieldbus options does 3RW5135-1XC14 support?

It supports PROFIBUS, Modbus RTU, and PROFINET onboard — no external gateway module required for these three common industrial networks.

What are the mounting clearances for 3RW5135-1XC14?

Required clearances: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, and 5 mm at the sides. The zero rear clearance allows flush back-panel mounting.