Siemens 3RW5135-1XC14-0S — Soft Starters

Siemens 3RW5135-1XC14-0S Soft Starter, 68 A min, 200-480 V

MPN3RW5135-1XC14-0S

Siemens 3RW5135-1XC14-0S soft starter, 68 A minimum, 200-480 V, Trip Class 10A/10E/20E, PROFIBUS/Modbus RTU/PROFINET, screw terminals, 203x185x324 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5135-1XC14-0S — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)75 W
Rated motor power at 230 V (40 °C)37 W
Rated operational current at 40 °C248 A
Rated operational current at 50 °C222 A
Rated operational current at 60 °C204 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)1 807 W
3RW5135-1XC14-0S — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5135-1XC14-0S — Protection & Features
ParameterValue
Motor overload protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3
3RW5135-1XC14-0S — Mechanical
ParameterValue
Height324 mm
Width185 mm
Depth203 mm
Weight6.45 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5135-1XC14-0S — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 mm; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5135-1XC14-0S — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC-53b
Product Feature Integrated Bypass Contact SystemNo
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5135-1XC14-0S — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

68 A minimum, 200-480 V — motor starting envelope

The 3RW5135-1XC14-0S: This soft starter is rated for a minimum motor FLA of 68 A and a supply range of 200 to 480 V, covering the common low-voltage motor population in European and North American industrial panels. Trip Class 10A (default), 10E, or 20E per IEC 60947-4-2 lets you match the overload protection to the motor thermal time constant — Class 10A for standard starts, 20E for high-inertia loads that need a longer acceleration ramp. Inside-delta circuit wiring is supported, which reduces the current through the starter thyristors to 58% of the motor line current — useful for larger motors where the starter frame size can be downsized.

PROFIBUS, Modbus RTU, PROFINET — fieldbus integration

Three fieldbus protocols are built in: PROFIBUS, Modbus RTU, and PROFINET, so the starter can be dropped into a Siemens S7 environment or a third-party PLC network without an external gateway. The analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI, giving the control system a real-time motor current or power signal for monitoring or trending. Firmware updates are field-loadable over the bus, which avoids pulling the unit for a firmware refresh when the plant automation standard changes.

Mounting and thermal derating — panel layout constraints

Dimensions are 203 mm deep, 185 mm wide, and 324 mm high, with screw fixing to the backplate — no DIN-rail clip, so plan for drilled and tapped mounting points. Clearance requirements: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind — the tight side clearance means adjacent devices can be butted up, but vertical airflow must be unobstructed.