Siemens 3RW5143-1XC14-0S Soft Starter, 90 A, 200-480 V

MPN3RW5143-1XC14-0S

Siemens 3RW5143-1XC14-0S soft starter, 90 A minimum, 200-480 V, Trip Class 10A, PROFIBUS, Modbus RTU, PROFINET, screw fixing, 417 x 210 x 203 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5143-1XC14-0S — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)110 W
Rated motor power at 230 V (40 °C)55 W
Rated operational current at 40 °C364 A
Rated operational current at 50 °C322 A
Rated operational current at 60 °C294 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)2 979 W
3RW5143-1XC14-0S — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5143-1XC14-0S — Protection & Features
ParameterValue
Motor overload protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5143-1XC14-0S — Mechanical
ParameterValue
Height417 mm
Width210 mm
Depth203 mm
Weight9.75 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5143-1XC14-0S — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 mm; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5143-1XC14-0S — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC-53b
Product Feature Integrated Bypass Contact SystemNo
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5143-1XC14-0S — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Panel fit and mounting constraints

The 3RW5143-1XC14-0S measures 417 mm high, 210 mm wide, and 203 mm deep, with screw fixing as the fastening method. The mounting position allows vertical surface mounting with ±90° rotation and ±22.5° tilt front-to-back, so panel layout can adapt to existing busbar or cable entry positions. Clearance requirements: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the sides, and 0 mm backwards. The zero backward clearance means the unit can sit flush against the back panel, simplifying depth planning in shallow enclosures.

Motor protection and trip class selection

Trip class is configurable: CLASS 10A (default), 10E, or 20E per IEC 60947-4-2. Minimum load is 15 % of the smallest settable Ie, so the soft starter can handle lightly loaded motors without nuisance tripping.

Fieldbus and control integration

Built-in PROFIBUS, Modbus RTU, and PROFINET interfaces allow direct connection to Siemens S7 or third-party controllers without an external gateway. The analog output is configurable as 4-20 mA (default) or 0-10 V, parameterizable via the High Feature HMI. Control circuit wiring uses screw-type terminals. Remote reset is available by cycling the control supply voltage. The unit supports firmware updates, an error logbook, and an auto-reset function for unattended restart after a fault clears.

Environmental and derating considerations

Shock resistance is 15 g / 11 ms (12 g / 11 ms with potential contact lifting). Vibration resistance: 15 mm to 6 Hz, 2 g to 500 Hz.

Frequently asked questions

How can I get pricing and availability for 3RW5143-1XC14-0S?

Submit an RFQ through the storefront.

MPN
3RW5143-1XC14-0S