Siemens 3RW5144-1XC14 SIRIUS Soft Starter, 100 A, 200-480 V

MPN3RW5144-1XC14

Siemens SIRIUS 3RW5144-1XC14 soft starter, 100 A minimum, 200-480 V, trip class 10A/10E/20E, screw fixing, 210 x 417 x 203 mm (WxHxD).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5144-1XC14 — Identification
ParameterValue
Product brand nameSIRIUS
3RW5144-1XC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)132 W
Rated motor power at 230 V (40 °C)75 W
Rated operational current at 40 °C433 A
Rated operational current at 50 °C381 A
Rated operational current at 60 °C346 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)3 188 W
3RW5144-1XC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5144-1XC14 — Protection & Features
ParameterValue
Motor overload protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5144-1XC14 — Mechanical
ParameterValue
Height417 mm
Width210 mm
Depth203 mm
Weight9.75 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5144-1XC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 mm; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5144-1XC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC-53b
Product Feature Integrated Bypass Contact SystemNo
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5144-1XC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Panel fit and mounting constraints

The 3RW5144-1XC14: Envelope is 210 mm wide, 417 mm high, 203 mm deep; clearance requirements are 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm sideways, and 0 mm backwards — plan the backplane and adjacent devices accordingly.

Operating envelope and derating

Rated for a minimum operating current of 100 A across 200-480 V — this is the floor for the motor FLA the starter must handle; the unit supports inside-delta wiring for reduced current draw. Trip class is configurable to CLASS 10A (default), 10E, or 20E per IEC 60947-4-2, matching the motor start profile without nuisance trips on high-inertia loads.

Fieldbus and HMI integration

Supports PROFIBUS, Modbus RTU, and PROFINET standard — the control circuit uses screw-type terminals; the fieldbus interface is onboard, no external gateway needed for these three protocols. Includes a standard HMI and a High Feature HMI option; the analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI parameter set. Firmware update capability and an error logbook are built in — supports traceable fault recording for qualification documentation.

Environmental and compliance robustness

Shock rated at 15 g / 11 ms (with potential contact lifting above 12 g / 11 ms); vibration resistance is 15 mm at 6 Hz and 2 g up to 500 Hz — suitable for rotating machinery and conveyor applications. Degree of pollution 3 per IEC 60947-4-2, meaning it tolerates conductive pollution in industrial atmospheres without conformal coating on the enclosure. Service factor is 1 — no continuous overload margin beyond the set current; the 15% minimum load relative to the smallest settable Ie ensures stable operation on lightly loaded motors.

Frequently asked questions

What fieldbus protocols does the 3RW5144-1XC14 support?

It supports PROFIBUS, Modbus RTU, and PROFINET standard. No external gateway module is required for these three protocols — the interface is onboard.

What are the mounting clearances for the 3RW5144-1XC14?

Requires 100 mm clearance above, 75 mm below, 10 mm in front, 5 mm to the sides, and 0 mm behind the unit.