Siemens 3RW5145-1XC14 SIRIUS Soft Starter, 135 A, 200-480 V

MPN3RW5145-1XC14

Siemens SIRIUS 3RW5145-1XC14 soft starter, 135 A minimum, 200-480 V, trip class 10A/10E/20E, PROFIBUS/Modbus RTU/PROFINET, screw terminals, 417x210x203 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5145-1XC14 — Identification
ParameterValue
Product brand nameSIRIUS
3RW5145-1XC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)160 W
Rated motor power at 230 V (40 °C)90 W
Rated operational current at 40 °C546 A
Rated operational current at 50 °C483 A
Rated operational current at 60 °C442 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 471 W
3RW5145-1XC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5145-1XC14 — Protection & Features
ParameterValue
Motor overload protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5145-1XC14 — Mechanical
ParameterValue
Height417 mm
Width210 mm
Depth203 mm
Weight9.75 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5145-1XC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 mm; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5145-1XC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC-53b
Product Feature Integrated Bypass Contact SystemNo
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5145-1XC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Panel fit — the 417 x 210 x 203 mm envelope

The 3RW5145-1XC14 measures 417 mm high by 210 mm wide by 203 mm deep. Mounting is screw-fix to a vertical surface; the unit can be rotated ±90° or tilted ±22.5° front-to-back. Clearance needs: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, 0 mm backward.

Motor protection — trip class and starting control

Trip class defaults to CLASS 10A per IEC 60947-4-2, with selectable 10E and 20E for heavier starting duty. The minimum settable motor current is 135 A, and the minimum load is 15% of that value. Starting voltage is adjustable 30-100%; stopping voltage is fixed at 50%. Soft torque and voltage ramp profiles are both available.

Fieldbus and I/O — what connects where

Three fieldbus options are built in: PROFIBUS, Modbus RTU, and PROFINET standard. The analog output is configurable as 4-20 mA (default) or 0-10 V when using the High Feature HMI. Control circuit wiring lands on screw-type terminals. A standard HMI and a High Feature HMI are both supported.

Environmental limits and derating

Operates from -25 °C to +60 °C, but derating applies at 40 °C and above. Shock rated 15 g / 11 ms. Vibration: 15 mm amplitude to 6 Hz, then 2 g to 500 Hz. Pollution degree 3 per IEC 60947-4-2. Inside-delta circuit wiring is supported for reduced line current.

Frequently asked questions

What fieldbus protocols does 3RW5145-1XC14 support?

PROFIBUS, Modbus RTU, and PROFINET standard are all built in.