Siemens 3RW5146-1XC14 — Soft Starters

Siemens 3RW5146-1XC14 SIRIUS Soft Starter, 160 A, 200-480 V

MPN3RW5146-1XC14

Siemens SIRIUS 3RW5146-1XC14 soft starter, 160 A minimum, 200-480 V, 50/60 Hz, PROFIBUS, Modbus RTU, PROFINET, screw fixing, 417 x 210 x 203 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5146-1XC14 — Identification
ParameterValue
Product brand nameSIRIUS
3RW5146-1XC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)200 W
Rated motor power at 230 V (40 °C)110 W
Rated operational current at 40 °C641 A
Rated operational current at 50 °C568 A
Rated operational current at 60 °C511 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 706 W
3RW5146-1XC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5146-1XC14 — Protection & Features
ParameterValue
Motor overload protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5146-1XC14 — Mechanical
ParameterValue
Height417 mm
Width210 mm
Depth203 mm
Weight9.75 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5146-1XC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 mm; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5146-1XC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC-53b
Product Feature Integrated Bypass Contact SystemNo
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5146-1XC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Mounting and panel fit — 417 × 210 × 203 mm

The 3RW5146-1XC14 measures 417 mm high, 210 mm wide, and 203 mm deep, with screw fixing to the mounting surface. Clearance requirements are specified: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the side, and 0 mm backwards. The mounting position allows ±90° rotation and ±22.5° tilt forward/backward from vertical. At 417 mm height, this unit occupies substantial vertical panel space. The 0 mm rear clearance means it can sit flush against a backplate, simplifying enclosure layout when depth is constrained.

Motor control ratings and trip class

Rated for a minimum operating current of 160 A across a supply voltage range of 200 to 480 V at 50 or 60 Hz. The trip class is selectable: CLASS 10A (default), 10E, or 20E per IEC 60947-4-2. The minimum load setting is 15% of the smallest settable Ie, which gives the soft starter the flexibility to handle lightly loaded motors without nuisance tripping. A service factor of 1 is specified.

Fieldbus and HMI connectivity

Built-in PROFIBUS, Modbus RTU, and PROFINET interfaces allow direct integration into common industrial networks without external gateways. The control circuit uses screw-type terminals. An analog output is configurable as 4–20 mA (default) or 0–10 V with the High Feature HMI, providing motor current or other process feedback to a PLC or drive panel meter. Two HMI variants are supported: a standard HMI and a High Feature HMI. The High Feature unit enables parameterization of the analog output signal type and access to the error logbook.

Starting and stopping profile

Voltage ramp start is standard, with starting voltage adjustable from 30% to 100% of line voltage. The stopping voltage is fixed at 50% and non-adjustable. A Soft Torque profile is available for reducing mechanical shock on the load during acceleration. The unit supports inside-delta circuit wiring, which reduces the current rating required for the soft starter by approximately 42% compared to standard in-line connection. This is a key consideration when retrofitting into an existing motor starter cabinet with limited ampacity.

Environmental limits and mechanical endurance

Pollution degree 3 per IEC 60947-4-2 means the unit is suited for industrial environments with conductive dust or occasional condensation. Shock resistance is 15 g / 11 ms (with potential contact lifting from 12 g / 11 ms), and vibration resistance is 15 mm at 6 Hz, 2 g to 500 Hz. These ratings support installation on machinery subject to moderate vibration, such as conveyor drives or compressor skids.

Reset and firmware capabilities

Auto-reset and remote reset are both supported — the remote reset is performed by cycling the control supply voltage off and on. Firmware updates are possible in the field, which is a consideration for validation engineers who need to document the firmware version at qualification.

Frequently asked questions

Where can I buy 3RW5146-1XC14 and how is it quoted?

This part is sourced through independent industrial distribution channels. Submit an RFQ for volume pricing and lead time.

What compliance documentation does Siemens provide for 3RW5146-1XC14?

The unit is designed to IEC 60947-4-2 for trip class and pollution degree. While specific RoHS, REACH, and UL declarations are not in the base record, standard Siemens SIRIUS documentation typically includes a CE declaration and materials compliance data on request.

MPN
3RW5146-1XC14