3RW5214-1AC04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5214-1AC04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)7.5 kW
Rated motor power at 230 V (40 °C)4 kW
Rated operational current at 40 °C31.5 A
Rated operational current at 50 °C28 A
Rated operational current at 60 °C23.9 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)241 W
3RW5214-1AC04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5214-1AC04 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5214-1AC04 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.1 kg
Mounting position+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5214-1AC04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5214-1AC04 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
3RW5214-1AC04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Soft starter for motor starting duty

The 3RW5214-1AC04: It is designed for controlled acceleration and deceleration of three-phase induction motors, reducing inrush current and mechanical stress on the driven load. Trip class is configurable to CLASS 10A (default), 10E, or 20E per IEC 60947-4-2, which means the starter can handle motor start profiles from normal to heavy-duty (e.g., high-inertia loads like centrifuges or crushers) without nuisance tripping during the acceleration ramp. Built-in fieldbus support includes PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET, so the starter integrates directly into a PLC-based control architecture without an external gateway. The analog output (4-20 mA default or 0-10 V parameterizable) provides current or load feedback to the controller for process monitoring. Soft Torque and Pump Ramp Down features are built in — the former reduces torque peaks during start for belted or geared loads, the latter prevents water hammer on pump deceleration by extending the stop ramp.

Mounting, wiring, and ambient limits

Dimensions are 275 mm height, 170 mm width, 152 mm depth. Fastening method is screw fixing — no DIN-rail clip; the unit bolts directly to the backplate. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, 0 mm backward. This covers both control wiring (smaller gauge) and power wiring (larger gauge) in a single clamp. Ambient temperature during operation is -25 to +60 °C, but derating applies above 40 °C. For a panel with internal heat rise, factor the motor current derating curve from the datasheet — the unit's thermal capacity drops above 40 °C ambient. Mounting position allows +/-10° rotation and can be tilted forward or backward on a vertical surface. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms with potential contact lifting — suitable for standard industrial panel vibration but not high-shock environments like stamping presses without additional isolation.

Approvals include CE marking, UL approval, and CSA approval — the unit carries the marks for North American and European panel acceptance without additional agency review. Firmware updates are supported, and an error logbook is available with special accessories. The unit supports auto-reset and remote reset (by cycling the 24 V control supply), which is useful for unattended restart after a fault clears.

Frequently asked questions

What fieldbus protocols does the 3RW5214-1AC04 support?

It supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET (with PROFIenergy capability via the PROFINET communication module). No external gateway is needed for direct PLC integration.

What are the clearance requirements for mounting the 3RW5214-1AC04?

Minimum clearances: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward. The unit is screw-fixed to the backplate, not DIN-rail mounted.