Siemens 3RW5214-1TC14

Siemens 3RW5214-1TC14 Soft Starter, 200-480 V, Class 10A

MPN 3RW5214-1TC14
Active

Siemens 3RW5214-1TC14 soft starter, 200-480 V rated voltage, 7.5 A minimum, Trip Class 10A (default)/10E/20E per IEC 60947-4-2, PROFIBUS/Modbus RTU/TCP/EtherNet/IP/PROFINET, UL/CSA/CE, 275 x 170 x 152 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5214-1TC14 specifications
ParameterValue
Mountingscrew fixing
Depth152 mm
Width170 mm
Height275 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

Trip class and motor protection for pump and conveyor starts

The 3RW5214-1TC14 is a hybrid switching device — a soft starter — whose trip class governs how long it can carry locked-rotor current during a start without thermally overloading the motor. Minimum settable load current is 7.5 A, with a minimum load of 15% relative to the smallest settable Ie — so the unit will not regulate below that threshold, which matters when commissioning a lightly loaded motor that draws less than the floor.

Fieldbus connectivity and remote control

This soft starter carries PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard interfaces onboard — no separate communication module needed for most plant networks. PROFIenergy is supported in connection with the PROFINET standard communication module, which allows the drive to respond to energy-management commands from the controller during idle phases. Firmware updates are possible via the fieldbus connection, and an error logbook is available but only in conjunction with special accessories — factor that into your commissioning toolkit if you rely on event history for root-cause analysis. Auto-reset is standard; remote reset is achieved by cycling the control supply voltage off and back on — a simple means of clearing a trip from a remote panel without a hardwired reset pushbutton.

Mounting clearances and ambient derating

The enclosure dimensions are 275 mm height, 170 mm width, 152 mm depth — screw fixing to the mounting plate. Clearance requirements: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the sides, 0 mm backwards. The backwards allowance of zero means the unit can sit flush against a backplate, which simplifies panel layout in tight cabinets. Shock resistance is 15 g / 11 ms, with potential contact lifting from 12 g / 11 ms — the unit holds the grid under normal vibration but the contacts may bounce if the panel is subjected to repeated shock events near that threshold.