Siemens 3RW5214-1TC15 — Soft Starters

Siemens 3RW5214-1TC15 Soft Starter, 200-600 V

MPN3RW5214-1TC15
Active

Siemens 3RW5214-1TC15 soft starter, 200-600 V rated voltage, Trip Class 10A, PROFIBUS/Modbus/EtherNet/IP/PROFINET, UL/CSA/CE, active production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5214-1TC15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5214-1TC15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)7.5 kW
Rated motor power at 230 V (40 °C)4 kW
Rated operational current at 40 °C31.5 A
Rated operational current at 50 °C28 A
Rated operational current at 60 °C23.9 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)241 W
3RW5214-1TC15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5214-1TC15 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5214-1TC15 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.1 kg
Mounting position+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5214-1TC15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5214-1TC15 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
3RW5214-1TC15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Trip class and motor protection — what CLASS 10A means for your load

The 3RW5214-1TC15 soft starter defaults to Trip Class 10A per IEC 60947-4-2, with selectable 10E and 20E classes. If your load has high inertia (centrifuge, crusher, long conveyor) and the acceleration time exceeds 10 seconds, switch to Class 20E to avoid nuisance trips during ramp-up.

Voltage range and fieldbus — global line compatibility

Rated 200-600 V, this unit covers 208 V, 240 V, 400 V, 480 V, and 600 V line voltages — one SKU for multi-voltage plants. Fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET. This covers most plant-floor networks without a gateway, but note that the PROFINET standard communication module is required for PROFIenergy support.

Mounting and clearance — panel layout constraints

Dimensions are 275 mm height × 170 mm width × 152 mm depth. The 152 mm depth is the critical dimension for shallow enclosures — verify your cabinet depth before committing. Clearance requirements: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind. The 100 mm top clearance is non-negotiable for airflow; stacking units without it will trigger thermal derating above 40 °C. Fastening is screw fixing on a vertical mounting surface, with ±10° rotation or tilt allowed. The solid conductor terminals accept 2× (1.0-2.5 mm²) and 2× (2.5-10 mm²) — this covers both control wiring and power connections without needing lug adapters for standard cable sizes.

Application features — pump ramp down and soft torque

Pump ramp down is a dedicated feature for pump applications — it gradually reduces voltage during stop to eliminate water hammer and pressure surges in the piping. Soft torque provides a gentler start for high-friction loads like conveyors with material on the belt, reducing mechanical shock to the drivetrain. Minimum load is 15% of the smallest settable Ie, and the minimum current rating is 7.5 A. This means the starter can handle lightly loaded motors down to about 1.1 kW at 400 V, but below that threshold the current sensing may be unreliable — size the starter to the motor FLA, not the motor power rating.

Lifecycle and compliance — active production, approvals on file

Shock resistance is 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms — this matters for applications near crushers, presses, or other high-vibration machinery.