Siemens 3RW5214-3AC14 — Soft Starters

Siemens 3RW5214-3AC14 Soft Starter, 200-480 V, 7.5 A min

MPN3RW5214-3AC14
Active

Siemens 3RW5214-3AC14 soft starter, 200-480 V rated, 7.5 A minimum current setting, Trip Class 10A/10E/20E, screw fixing, 275 x 170 x 152 mm, UL, CSA, CE.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5214-3AC14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5214-3AC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)7.5 kW
Rated motor power at 230 V (40 °C)4 kW
Rated operational current at 40 °C31.5 A
Rated operational current at 50 °C28 A
Rated operational current at 60 °C23.9 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)241 W
3RW5214-3AC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5214-3AC14 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5214-3AC14 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.1 kg
Mounting position+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5214-3AC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5214-3AC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
3RW5214-3AC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Rated voltage and motor current range — what fits

The 3RW5214-3AC14: Rated 200 to 480 V, covering the common low-voltage motor networks in North America (208, 240, 480 V) and Europe (230, 400 V). The minimum settable motor current is 7.5 A, so this starter is sized for motor FLA down to that floor — anything smaller needs a different frame. Also selectable 10E or 20E for longer acceleration profiles.

Mounting and clearance — panel layout constraints

Screw-fixing mount, 275 mm high, 170 mm wide, 152 mm deep. Requires 100 mm free space above, 75 mm below, 10 mm forward, 5 mm sideways, 0 mm backward — tight on the rear, so the panel backplane must be clear behind the mounting plate. Mounting position allows ±10° tilt from vertical, so a slight rack angle in the enclosure is acceptable.

Fieldbus and control integration

PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard — covers the four major industrial Ethernet and serial fieldbuses. PROFIenergy supported via the PROFINET communication module for energy management during idle phases. Analog output configurable as 4-20 mA (default) or 0-10 V for feeding motor current or load signal to a PLC or local display. Remote reset by cycling the control supply voltage — useful for unattended restart after a fault.

Environmental limits and approvals

Operating ambient -25 to +60 °C, with derating required above 40 °C — plan the panel ventilation if the enclosure ambient exceeds 40 °C. Shock resistance 15 g / 11 ms (12 g with potential contact lifting). UL, CSA, and CE marked — accepted for North American and European installations without additional agency review.

Frequently asked questions

What is the minimum motor current I can set on 3RW5214-3AC14?

Minimum settable motor current is 7.5 A, which is 15 % of the smallest adjustable Ie range. Motors with FLA below 7.5 A need a smaller-frame soft starter.

What compliance documentation does Siemens provide for 3RW5214-3AC14?

The unit carries UL approval, CSA approval, and CE marking — the key regulatory documents for North America and the EU. RoHS and REACH compliance is standard for current-production Siemens soft starters but not separately listed in this data.

MPN
3RW5214-3AC14