Skip to main content
Siemens 3RW5215-3TC15 — Soft Starters

Siemens 3RW5215-3TC15 Soft Starter, 11.5 A, 200-600 V

MPN3RW5215-3TC15
Active

Siemens 3RW5215-3TC15 SIRIUS soft starter, 11.5 A minimum, 200-600 V rated, Class 10A trip, PROFIBUS/Modbus RTU/EtherNet/IP/PROFINET, screw fixing, 275 x 170 x 152 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5215-3TC15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5215-3TC15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)11 kW
Rated motor power at 230 V (40 °C)5.5 kW
Rated operational current at 40 °C43.3 A
Rated operational current at 50 °C39 A
Rated operational current at 60 °C33.9 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)318 W

Control & Connection

3RW5215-3TC15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5215-3TC15 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5215-3TC15 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.1 kg
Mounting position+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5215-3TC15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5215-3TC15 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5215-3TC15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Trip class and starting duty

The 3RW5215-3TC15 is configured for Class 10A as default, with selectable Class 10E and Class 20E per IEC 60947-4-2. The 10E and 20E options extend the thermal budget for longer ramp times on loads like centrifuges or crushers. Minimum operating current is 11.5 A, with a minimum load of 15 % relative to the smallest settable Ie. Below that threshold the current sensing may not resolve accurately, so the unit is sized for motors drawing at least 11.5 A at full load.

Line voltage and control supply

Rated operational voltage spans 200... 600 V AC, covering the common global low-voltage motor networks: 208 V, 240 V, 400 V, 480 V, and 575 V systems. Ambient operating range is -25... +60 °C, with derating required above 40 °C. In a non-ventilated enclosure at 50 °C ambient, expect to reduce the continuous current rating per the derating curve in the manual — the spec table flags this explicitly.

Fieldbus and integration

The unit ships with onboard PROFIBUS DP, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard connectivity. PROFIenergy is supported when used with the PROFINET communication module, enabling energy-management profiles during idle periods. This is a multi-protocol soft starter — no separate gateway module needed for most plant-floor networks. Clearance requirements: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the sides, and 0 mm backwards — the back can sit flush against the panel backplate. Overall dimensions are 275 mm height, 170 mm width, 152 mm depth. Solid wire terminations accept 2x (1.0... 2.5 mm²) and 2x (2.5... 10 mm²) — the dual-entry allows daisy-chaining the line and load conductors without separate terminal blocks for the power circuit.

Lifecycle and approvals

For volume or blanket-order pricing, submit an RFQ with the target quantity and delivery window.

Frequently asked questions

What trip classes does the 3RW5215-3TC15 support?

Default is Class 10A, with selectable Class 10E and Class 20E per IEC 60947-4-2. Class 10A provides a 10-second thermal memory at 7.2× FLC, suitable for standard starting duty. Class 10E and 20E extend the ramp time for higher-inertia loads.

What fieldbus protocols are supported on the 3RW5215-3TC15?

Onboard protocols include PROFIBUS DP, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard. PROFIenergy is supported with the PROFINET communication module. No external gateway is required for these networks.

What are the mounting clearances for the 3RW5215-3TC15?

Required clearances: 100 mm above, 75 mm below, 10 mm in front, 5 mm on each side, and 0 mm behind — the back can mount flush to the panel.

What compliance documentation does Siemens provide for the 3RW5215-3TC15?

The unit carries CE marking for the European market, UL approval for North America, and CSA approval for Canada. These cover the applicable IEC, NEC, and CEC installation standards.

MPN
3RW5215-3TC15