Siemens 3RW5216-1AC04 — Soft Starters

Siemens 3RW5216-1AC04 Soft Starter, 14 A, 200–480 V, SIRIUS

MPN3RW5216-1AC04
Active

Siemens SIRIUS 3RW5216-1AC04 soft starter, 14 A minimum, 200–480 V rated, trip class 10A, PROFIBUS/Modbus/EtherNet/IP/PROFINET, screw fixing, 275 x 170 x 152 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5216-1AC04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5216-1AC04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)15 kW
Rated motor power at 230 V (40 °C)7.5 kW
Rated operational current at 40 °C55.4 A
Rated operational current at 50 °C49 A
Rated operational current at 60 °C45 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)449 W

Control & Connection

3RW5216-1AC04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5216-1AC04 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5216-1AC04 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5216-1AC04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5216-1AC04 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5216-1AC04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Panel fit and mounting dimensions

The 3RW5216-1AC04 measures 275 mm high by 170 mm wide by 152 mm deep, screw-fixed to the mounting plate. Clearance requirements: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the sides, and zero backwards — plan the gland plate and busbar routing around these gaps. Solid-wire terminals accept 2x 1.0–2.5 mm² and 2x 2.5–10 mm², covering both control and power wiring without lug adapters.

Motor starting profile and trip class

Also selectable CLASS 10E or 20E for higher-inertia loads like centrifuges or crushers. Rated voltage range 200–480 V covers common low-voltage networks worldwide; the unit includes a service factor of 1, so no continuous overload margin beyond the set current. Operating ambient -25 to +60 °C, with derating required above 40 °C — factor this into the panel thermal design if the enclosure runs hot.

Fieldbus and control integration

Built-in PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET with PROFIenergy support — no separate communication module needed for most networks. The PROFINET standard module enables energy profiling per PROFIenergy for coordinated load shedding during idle periods. Analog output configurable as 4–20 mA (default) or 0–10 V via the High Feature HMI, giving the PLC a real-time current or torque signal. Remote reset by cycling the 24 V DC control supply. Soft Torque and Pump Ramp Down reduce mechanical shock on conveyors and prevent water hammer in pump starts/stops — both parameterizable without external timers.

Lifecycle and sourcing

UL, CSA, and CE markings are on file, covering installations in North America and the European Union without additional certification paperwork.

Frequently asked questions

Where can I buy the 3RW5216-1AC04 and get a price?

Submit an RFQ for current pricing and lead time — availability is confirmed at quote time.

What compliance documentation does Siemens provide for the 3RW5216-1AC04?

The unit carries CE marking for the European market, plus UL and CSA approvals for North American installations. RoHS and REACH declarations are standard with the shipment.

MPN
3RW5216-1AC04