Siemens 3RW5216-3AC04 — Soft Starters

Siemens 3RW5216-3AC04 SIRIUS Soft Starter, 200-480 V, 14 A

MPN3RW5216-3AC04
Active

Siemens SIRIUS 3RW5216-3AC04 soft starter, 200-480 VAC, 14 A minimum, Class 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP, screw fixing, 275x170x152 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5216-3AC04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5216-3AC04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)15 kW
Rated motor power at 230 V (40 °C)7.5 kW
Rated operational current at 40 °C55.4 A
Rated operational current at 50 °C49 A
Rated operational current at 60 °C45 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)449 W

Control & Connection

3RW5216-3AC04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5216-3AC04 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5216-3AC04 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5216-3AC04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5216-3AC04 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5216-3AC04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

SIRIUS 3RW52 — what this soft starter covers

The Siemens 3RW5216-3AC04 is a SIRIUS hybrid soft starter sized for three-phase motors from 200 to 480 VAC, with a minimum setting current of 14 A — that's the floor for the motor FLA you can program into it. It ships with a default trip class of CLASS 10A per IEC 60947-4-2, meaning it protects the motor during start-up by limiting the thermal stress to within 10 seconds of locked-rotor current at the set overload. You can also select CLASS 10E or 20E if the application needs a longer acceleration window.

Fieldbus fit and control integration

The 3RW5216-3AC04 carries onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — you don't need a separate communication module for any of these. It also supports PROFIenergy in conjunction with the PROFINET standard communication module. The analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI, giving the PLC a real-time current or voltage signal for monitoring motor load or ramp status. Remote reset is handled by cycling the 24 VDC control supply off and back on — no need to walk to the panel for a manual reset after a fault trip.

Mounting, cooling, and environmental limits

Mounting is screw-fix to a vertical surface; the unit can be rotated ±90° or tilted ±22.5° front-to-back, which helps when fitting into tight enclosures or existing backpanels. Dimensions are 275 mm high, 170 mm wide, 152 mm deep — the depth is the key number for enclosure depth clearance. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and zero behind. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if potential contact lifting is a concern.

Pump and process-specific features

Pump Ramp Down and Soft Torque are built in — these are the two features that matter for centrifugal pumps: the ramp-down prevents water hammer on stop, and soft torque reduces the initial current surge on start. The minimum load setting is 15 % of the smallest settable Ie, which means it can handle lightly loaded motors without nuisance tripping on the underload curve. Auto-reset is supported, and an error logbook is available but only with special accessories — not standard out of the box.

Approvals and compliance documentation

CE marked for the European market, UL and CSA approved for North American installations — the nameplate carries all three marks, so it passes inspection for panels shipping to either region. Firmware updates are field-loadable, which means you can apply later revisions without swapping the unit.

Frequently asked questions

What is the 3RW5216-3AC04 used for?

It's a SIRIUS hybrid soft starter for three-phase induction motors, typically on pumps, conveyors, fans, and compressors where you need to limit inrush current and control acceleration torque. The voltage range is 200-480 VAC, minimum motor FLA is 14 A, and the trip class is selectable between 10A, 10E, and 20E per IEC 60947-4-2.

MPN
3RW5216-3AC04