Skip to main content
Siemens 3RW5217-3AC05 — Soft Starters

Siemens 3RW5217-3AC05 SIRIUS Soft Starter, 15.5 A, 200-600 V

MPN3RW5217-3AC05
Active

Siemens SIRIUS 3RW5217-3AC05 soft starter, 15.5 A minimum, 200-600 V, Trip Class 10A, multi-protocol communications, screw fixing, 275 H x 170 W x 152 D mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5217-3AC05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5217-3AC05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)18.5 kW
Rated motor power at 230 V (40 °C)11 kW
Rated operational current at 40 °C65.8 A
Rated operational current at 50 °C58 A
Rated operational current at 60 °C52.8 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)526 W

Control & Connection

3RW5217-3AC05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5217-3AC05 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5217-3AC05 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5217-3AC05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5217-3AC05 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5217-3AC05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Active production, multi-protocol soft starter for 200-600 V

The 3RW5217-3AC05: Trip Class 10A is the default setting per IEC 60947-4-2, meaning it protects standard squirrel-cage motors during start-up without nuisance tripping on normal acceleration profiles for pumps, fans, and compressors. Fieldbus connectivity includes PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET onboard — no separate communication module needed for most common industrial networks.

Panel fit and ambient limits

Mounts via screw fixing to a vertical surface; the enclosure dimensions are 275 mm height, 170 mm width, and 152 mm depth — confirm the backpanel clearance before layout. Clearance requirements: 100 mm above, 75 mm below, 10 mm front, 5 mm sides, 0 mm rear. Solid wire terminals accept 2x (1.0-2.5 mm²) and 2x (2.5-10 mm²) — suitable for standard control and power wiring without compression lugs.

Carries both UL and CSA approvals, plus CE marking — accepted in North American and European installations without additional agency review. Service factor is 1.0 — no overload margin beyond nameplate rating; set the motor FLA accurately in the soft starter parameters. Vibration resistance tested to 15 g / 11 ms shock, with potential contact lifting above 12 g / 11 ms — adequate for standard industrial environments but verify for high-shock applications.

Frequently asked questions

Where can I buy 3RW5217-3AC05 and get a price?

Sourced to order against a BOM quantity through independent industrial distribution.

What compliance documentation does Siemens provide for 3RW5217-3AC05?

The unit carries UL approval, CSA approval, and CE marking. No RoHS or REACH statements are in this record, but Siemens typically provides those on request.

MPN