Skip to main content
Siemens 3RW5224-1TC15

Siemens 3RW5224-1TC15 SIRIUS Soft Starter, 20 A, 200-600 V

MPN 3RW5224-1TC15
Active

Siemens SIRIUS 3RW5224-1TC15 soft starter, 20 A minimum adjustable current, 200-600 V rated voltage, Trip Class 10A/10E/20E per IEC 60947-4-2, screw fixing, 203 x 185 x 306 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5224-1TC15 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

Soft starter for motor starting — what the ratings mean

The 3RW5224-1TC15: The Trip Class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2 — this sets the maximum allowed starting time before the overload protection trips, so you match it to the motor's acceleration profile. A CLASS 10A trip gives you about 10 seconds of starting time at 7.2x Ie;. The unit supports multiple fieldbus protocols natively: PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — so it drops into most automation architectures without a separate gateway.

Mounting and panel integration

The soft starter measures 203 mm deep, 185 mm wide, and 306 mm high, and uses screw fixing for panel mounting. Clearance requirements are specified: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, and 5 mm at the side — so plan the DIN rail and enclosure layout around these gaps, especially the 100 mm above for airflow and cable bend radius. The mounting position allows +/- 10° rotation and can be tilted forward or backward on a vertical surface. Shock resistance is rated at 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms, which is fine for most industrial panels but worth checking if the enclosure is near a large press or crusher.

Application features and compliance

This soft starter includes Soft Torque and Pump Ramp Down features — the soft torque profile reduces mechanical stress on belts and gears during start, and the pump ramp down gradually reduces speed to prevent water hammer in pumping systems. A remote reset is available by cycling the control supply voltage, and the unit supports auto-reset for unattended operation. The minimum load is 15 % relative to the smallest settable Ie, so it can handle lightly loaded motors without nuisance tripping. Approvals include UL, CSA, and CE marking — the part is accepted for North American and European installations. The product category is hybrid switching devices, part of the SIRIUS brand family. Firmware updates are supported, and an error logbook is available only with special accessories. There is no analog output and no torque control; this is a standard soft starter, not a closed-loop torque controller.

MPN
3RW5224-1TC15