Siemens 3RW5225-1TC15 — Soft Starters

Siemens 3RW5225-1TC15 SIRIUS Soft Starter, 200-600 V

MPN3RW5225-1TC15
Active

Siemens SIRIUS 3RW5225-1TC15 soft starter, 200-600 VAC, 25.5 A minimum setting, Class 10A/10E/20E trip class, screw fixing, 306 x 185 x 203 mm (HxWxD).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5225-1TC15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5225-1TC15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)30 kW
Rated motor power at 230 V (40 °C)18.5 kW
Rated operational current at 40 °C109 A
Rated operational current at 50 °C96 A
Rated operational current at 60 °C87.5 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)744 W
3RW5225-1TC15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5225-1TC15 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5225-1TC15 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight5.6 kg
Mounting position+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5225-1TC15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5225-1TC15 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
3RW5225-1TC15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

SIRIUS 3RW52 — what this soft starter does on the line

The 3RW5225-1TC15: Trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2 — the standard that governs motor-starter coordination. Minimum settable current is 25.5 A, with a minimum load threshold of 15 % relative to the smallest settable Ie — relevant when the motor FLA falls near the bottom of the adjustment range.

Fieldbus and control — what connects where

The 3RW5225-1TC15 ships with onboard PROFIBUS DP and PROFINET standard interfaces, plus Modbus RTU, Modbus TCP, and EtherNet/IP — five fieldbus protocols on one base unit without an add-on module. PROFIenergy is supported in conjunction with the PROFINET standard communication module. Remote reset is available by cycling the control supply off and on — no separate reset signal wire needed. Firmware updates are field-loadable. An error logbook function is present but requires special accessories (not included in the base unit).

Panel fit — dimensions, mounting, and clearances

Envelope is 306 mm high, 185 mm wide, 203 mm deep. Required clearances: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, 0 mm behind. The mounting surface can be tilted ±10° forward or backward on a vertical plane.

Approvals and environmental limits

Carries CE marking, UL approval, and CSA approval — accepted across North American and European installations without additional agency review. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if contact lifting is a concern.

Pump-specific features and soft torque

Soft Torque and Pump Ramp Down are both available — the ramp-down feature reduces pressure surge on pump shutdown by gradually reducing motor voltage rather than coasting to stop. Auto-reset is configurable. Analog output and torque control are not provided on this variant (HMI-High Feature is also absent).

Frequently asked questions

What is the trip class of the 3RW5225-1TC15 and what does it mean?

Trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2. CLASS 20E extends the trip time for high-inertia loads that need a longer acceleration ramp.

What fieldbus protocols does the 3RW5225-1TC15 support?

Onboard protocols are PROFIBUS DP, PROFINET standard, Modbus RTU, Modbus TCP, and EtherNet/IP. PROFIenergy is supported when used with the PROFINET standard communication module.

What approvals does the 3RW5225-1TC15 carry?

CE marking for the European market, UL approval for the US, and CSA approval for Canada. These cover the base unit for panel integration without additional agency testing.

What are the mounting clearances required for the 3RW5225-1TC15?

Minimum clearances: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, 0 mm behind. The unit is screw-fixed (not DIN-rail mounted) and can be tilted ±10° on a vertical surface.