Siemens 3RW5225-3AC14 — Soft Starters

Siemens 3RW5225-3AC14 SIRIUS Soft Starter, 25.5 A, 200-480 V

MPN3RW5225-3AC14
Active

Siemens SIRIUS 3RW5225-3AC14 soft starter, 25.5 A minimum setting, 200-480 V rated voltage, trip class 10A/10E/20E per IEC 60947-4-2, multi-protocol onboard, screw fixing, 306 x 185 x 203 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5225-3AC14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5225-3AC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)30 kW
Rated motor power at 230 V (40 °C)18.5 kW
Rated operational current at 40 °C109 A
Rated operational current at 50 °C96 A
Rated operational current at 60 °C87.5 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)744 W

Control & Connection

3RW5225-3AC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebox terminal
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5225-3AC14 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5225-3AC14 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight5.6 kg
Mounting position+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5225-3AC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5225-3AC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5225-3AC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Active production — what that means for procurement

The 3RW5225-3AC14 carries a current lifecycle stage, meaning Siemens still manufactures it as a standard catalog item. No last-time-buy window or phase-out notice is in effect.

Trip class and motor starting duty

The unit also offers selectable 10E and 20E classes for higher-inertia loads like centrifuges or crushers that need a longer acceleration ramp. The minimum settable current is 25.5 A, so motors with a full-load current below that value require a smaller frame size. The rated voltage range of 200–480 V covers the common low-voltage supplies worldwide without a hardware tap change.

Onboard communications — no extra module needed

PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard are all built into the base unit. This eliminates the cost and panel space of a separate communication module for most industrial networks. PROFIenergy is supported when used with the PROFINET standard communication module, enabling energy management functions during idle periods.

Soft Torque and Pump Ramp Down — mechanical stress reduction

Soft Torque reduces the initial current spike and mechanical shock on start, which extends the life of belts, gears, and couplings. Pump Ramp Down provides a controlled deceleration on stop, preventing water hammer in pumping systems.

Mounting and panel integration

Mounting is by screw fixing, not DIN-rail clip. The dimensions are 306 mm height, 185 mm width, and 203 mm depth. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward. The mounting position allows ±10° rotation and can be tilted forward or backward on a vertical surface.

UL, CSA, and CE markings are all present, so the unit is accepted in North American and European installations without additional certification work. Shock resistance is rated at 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms. The service factor is 1.0.