Siemens 3RW5226-1AC05 SIRIUS Soft Starter, 32 A, 200-600 V

MPN3RW5226-1AC05
Active

Siemens SIRIUS 3RW5226-1AC05 soft starter, 32 A minimum, 200-600 V rated, Trip Class 10A/10E/20E per IEC 60947-4-2, screw fixing, 185 x 306 x 203 mm (WxHxD).

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5226-1AC05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5226-1AC05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)37 kW
Rated motor power at 230 V (40 °C)22 kW
Rated operational current at 40 °C133 A
Rated operational current at 50 °C118 A
Rated operational current at 60 °C107 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)933 W

Control & Connection

3RW5226-1AC05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5226-1AC05 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5226-1AC05 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight5.6 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5226-1AC05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5226-1AC05 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5226-1AC05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Soft starter for motor starting duty

The Siemens 3RW5226-1AC05 is a SIRIUS soft starter rated for a minimum motor current of 32 A across a 200-600 V supply range. Built-in fieldbus options cover Modbus RTU, Modbus TCP, PROFIBUS, PROFINET, and EtherNet/IP, so it drops into most PLC architectures without an extra gateway. The analog output defaults to 4-20 mA (or 0-10 V with the High Feature HMI) for feeding motor current to a SCADA trend. Mounting is screw-fixed on a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back, which helps when panel layout is tight. Free-air clearance: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides — plan the gland plate and ventilation accordingly.

Frequently asked questions

Is 3RW5226-1AC05 compatible with Modbus TCP?

Yes, the 3RW5226-1AC05 supports Modbus TCP natively, along with Modbus RTU, PROFIBUS, PROFINET, and EtherNet/IP.

What is the trip class of 3RW5226-1AC05?

The trip class defaults to CLASS 10A per IEC 60947-4-2, with selectable 10E or 20E for heavier starting loads.

MPN
3RW5226-1AC05