Siemens 3RW5226-3AC04 — Soft Starters

Siemens 3RW5226-3AC04 SIRIUS Soft Starter, 32 A, 200-480 V

MPN3RW5226-3AC04
Active

Siemens SIRIUS 3RW5226-3AC04 soft starter, 32 A minimum, 200-480 V, Class 10A/10E/20E, PROFINET, Modbus RTU/TCP, EtherNet/IP, screw fixing, 306 x 185 x 203 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5226-3AC04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5226-3AC04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)37 kW
Rated motor power at 230 V (40 °C)22 kW
Rated operational current at 40 °C133 A
Rated operational current at 50 °C118 A
Rated operational current at 60 °C107 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)933 W

Control & Connection

3RW5226-3AC04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebox terminal
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5226-3AC04 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5226-3AC04 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight5.6 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5226-3AC04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5226-3AC04 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5226-3AC04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

SIRIUS 3RW52 — fieldbus-ready soft starter for motor starting

The Siemens 3RW5226-3AC04 is a SIRIUS-brand hybrid soft starter rated for a minimum operating current of 32 A across a 200-480 V supply range. It integrates PROFINET, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFIBUS communication, making it a drop-in for multi-protocol control architectures. Trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2, giving the commissioning engineer flexibility to match the motor thermal model and starting duty cycle without swapping hardware. The unit measures 306 mm high, 185 mm wide, and 203 mm deep, with screw-fixing mounting and a ±90° rotatable mounting surface — the panel layout can tilt ±22.5° front-to-back without losing the vertical orientation spec.

Clearance and ambient derating — panel integration constraints

Minimum clearance around the unit: 100 mm upwards, 75 mm downwards, 10 mm forwards, 0 mm backwards, 5 mm at the sides. These gaps govern the enclosure fill factor — the backwards zero-clearance spec means the backplane can be flush against the mounting plate.

Fieldbus slice and control features — what the integrator needs

PROFINET standard with PROFIenergy support (requires the PROFINET communication module) enables energy management during idle phases — useful for conveyor or pump lines with intermittent duty. Analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI parameterization, giving the site electrical engineer a direct process-variable signal back to the PLC without a separate transducer. Soft Torque and Pump Ramp Down features are built in — the pump ramp down reduces water hammer on stop, while Soft Torque lowers the starting torque for belt-driven loads. Auto-reset and remote reset (by cycling the control supply voltage) are supported, with an error logbook available only with special accessories — the commissioning engineer should verify the accessory kit is ordered if fault logging is needed.

Certification and compliance — documentation for the MRO file

Shock resistance is rated 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms — relevant for marine or mobile equipment installations where vibration is a concern. Minimum load is 15% relative to the smallest settable Ie — the MRO planner should confirm the motor FLA stays above this threshold to avoid nuisance tripping on lightly loaded motors.

Frequently asked questions

What fieldbus protocols does 3RW5226-3AC04 support?

It supports PROFINET, PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. PROFIenergy is available when the PROFINET communication module is fitted.

What are the clearance requirements for 3RW5226-3AC04 in a panel?

Minimum clearances: 100 mm above, 75 mm below, 10 mm forward, 0 mm backward, and 5 mm at the sides. Backwards clearance is zero — the unit can mount flush against the backplane.

What compliance documentation does Siemens provide for 3RW5226-3AC04?

The unit is rated pollution degree 3 per IEC 60947-4-2 and carries the relevant markings for industrial control equipment.

MPN
3RW5226-3AC04