Skip to main content
Siemens 3RW5226-3TC04 — Soft Starters

Siemens SIRIUS 3RW5226-3TC04 Soft Starter, 32 A, 200-480 V

MPN3RW5226-3TC04
Active

Siemens SIRIUS 3RW5226-3TC04 hybrid soft starter, 32 A minimum, 200-480 V rated, Trip Class 10A/10E/20E per IEC 60947-4-2, screw fixing, 306 x 185 x 203 mm (HxWxD).

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5226-3TC04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5226-3TC04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)37 kW
Rated motor power at 230 V (40 °C)22 kW
Rated operational current at 40 °C133 A
Rated operational current at 50 °C118 A
Rated operational current at 60 °C107 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)933 W

Control & Connection

3RW5226-3TC04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebox terminal
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5226-3TC04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5226-3TC04 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight5.6 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5226-3TC04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5226-3TC04 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5226-3TC04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

What the 32 A minimum rating means for fit

The Siemens SIRIUS 3RW5226-3TC04 is a hybrid soft starter with a minimum operating current of 32 A, which means it is sized for motor loads drawing at least that much at full load — not a fractional-horsepower machine. The 200-480 V rated supply covers most common three-phase industrial voltages across North America and Europe. Trip Class 10A (default), 10E, or 20E per IEC 60947-4-2 gives you the choice: 10A for standard-start loads like pumps and fans where you need fast protection, or 20E for higher-inertia loads that take longer to spin up. The 24 V DC control supply is standard for modern PLC-driven panels. This is a current-production part — lifecycle status is active, so you are not chasing last-time-buy inventory.

Communication and control flexibility

The 3RW5226-3TC04 supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard. That covers essentially every major industrial Ethernet and fieldbus in use — no need for a separate gateway module for most plants. PROFIenergy is supported when used with the PROFINET communication module, useful for energy management during idle periods. It also includes Soft Torque and Pump Ramp Down features, which reduce mechanical stress on the load and prevent water hammer in pump applications. Auto-reset and remote reset (by cycling the control supply voltage) are built in, so you can integrate it into automated restart sequences without an external timer.

Mounting and environmental considerations

Mounting is screw fixing onto a vertical surface, with the unit rotatable +/-90° and tiltable +/-22.5° front-to-back. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward. The 306 x 185 x 203 mm (HxWxD) footprint fits standard enclosure backplates, but plan for the 100 mm top clearance — that is the tightest dimension. Shock resistance is 15 g / 11 ms (12 g / 11 ms with potential contact lifting).

Frequently asked questions

What are the communication protocols supported by 3RW5226-3TC04?

The 3RW5226-3TC04 supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard. PROFIenergy is supported when used with the PROFINET communication module.

Is 3RW5226-3TC04 compatible with Ethernet/IP?

Yes, EtherNet/IP is supported directly on this unit — no additional gateway or communication module is required for basic EtherNet/IP connectivity.

What is 3RW5226-3TC04's listed depth (203 mm) on this component line?

The depth is 203 mm, with a width of 185 mm and height of 306 mm. Mounting is screw fixing with required clearances of 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward.

MPN
3RW5226-3TC04