Siemens 3RW5234-6TC05 — Soft Starters

Siemens 3RW5234-6TC05 Soft Starter, 53 A, 200-600 V, SIRIUS

MPN3RW5234-6TC05
Active

Siemens SIRIUS 3RW5234-6TC05 soft starter, 53 A minimum, 200-600 V rated, Class 10A/10E/20E trip, PROFIBUS/Modbus RTU/Modbus TCP/EtherNet/IP/PROFINET, 306x185x203 mm, screw fixing.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5234-6TC05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5234-6TC05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)55 kW
Rated motor power at 230 V (40 °C)30 kW
Rated operational current at 40 °C196 A
Rated operational current at 50 °C175 A
Rated operational current at 60 °C154 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)1 291 W
3RW5234-6TC05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5234-6TC05 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5234-6TC05 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight6.6 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5234-6TC05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5234-6TC05 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
3RW5234-6TC05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Form factor and mounting — panel fit for a 306 x 185 x 203 mm frame

The 3RW5234-6TC05 measures 306 mm high by 185 mm wide by 203 mm deep, screw-fixed to a vertical mounting surface with ±90° rotation and ±22.5° tilt front-to-back allowed. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm sideways, zero backward — plan the gland plate and busbar routing accordingly.

Trip class and motor protection — Class 10A default, 10E and 20E selectable

Default trip class is 10A per IEC 60947-4-2, with selectable 10E and 20E for higher-inertia loads like centrifuges or crushers. The minimum settable current is 53 A, with a 15 % minimum load relative to that Ie — so the soft starter handles motors down to about 8 A if the BOM calls for a wide current range.

Fieldbus connectivity — PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET

Onboard PROFIBUS and Modbus RTU, plus Modbus TCP, EtherNet/IP, and PROFINET standard — no separate communication module needed for most plant networks. PROFIenergy is supported via the PROFINET interface, useful for coordinated energy management during idle phases.

Operating temperature and derating — -25 to +60 °C, derate above 40 °C

Rated for -25 to +60 °C during operation, but Siemens explicitly notes derating at 40 °C or above — size the enclosure ventilation and check the ambient against the load profile if the panel sits near a heat source. Pollution degree 3 per IEC 60947-4-2 means the unit tolerates conductive dust and humidity typical of industrial floors.

Pump and soft-torque features — pump ramp down, soft torque, auto-reset

Includes pump ramp down to avoid water hammer on stop, and soft torque for gentle acceleration of conveyors or fans. Auto-reset is standard; remote reset is possible by cycling the 24 V control supply. The error logbook is accessible with the optional accessory — useful for fault analysis during commissioning.

Approvals and compliance — UL, CSA, CE, shock resistance 15 g

UL and CSA approved, CE marked — covers North American and European installations. Shock resistance is 15 g / 11 ms, with potential contact lifting noted at 12 g / 11 ms; the unit holds the line under moderate vibration but should not be mounted directly on a reciprocating compressor frame without isolation.

Frequently asked questions

What compliance documentation does Siemens provide for 3RW5234-6TC05?

The unit carries UL approval, CSA approval, and CE marking. Pollution degree 3 per IEC 60947-4-2 is specified. RoHS and REACH documentation is typically available from Siemens upon request, though not listed in the spec record.

MPN
3RW5234-6TC05