Siemens 3RW5236-6AC05 SIRIUS Soft Starter, 81 A, 200-600 V

MPN3RW5236-6AC05
Active

Siemens SIRIUS 3RW5236-6AC05 soft starter, 81 A minimum, 200-600 V, Class 10A/10E/20E, screw fixing, 306x185x203 mm, CE/UL/CSA.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5236-6AC05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5236-6AC05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)90 kW
Rated motor power at 230 V (40 °C)45 kW
Rated operational current at 40 °C296 A
Rated operational current at 50 °C265 A
Rated operational current at 60 °C244 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)2 037 W
3RW5236-6AC05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5236-6AC05 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5236-6AC05 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight7.15 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5236-6AC05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5236-6AC05 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
3RW5236-6AC05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

81 A minimum, 200-600 V — SIRIUS soft starter for motor starting duty

The Siemens 3RW5236-6AC05 is a SIRIUS hybrid soft starter rated for a minimum operating current of 81 A across a 200-600 V supply range. This puts it in the mid-range of the 3RW52 family, sized for motors that draw 81 A or more during start — typically 30-50 kW depending on voltage and load type. Trip class is selectable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2. For a pump or conveyor with a moderate inertia load, Class 10A gives a 10-second thermal limit at 7.2× Ie; Class 20E doubles that window for high-inertia starts like centrifuges or crushers. The default 10A is fine for most fan and pump applications, but if the motor takes longer than 10 seconds to reach speed, switch to 20E via the parameter set. In a panel with other heat sources — drives, transformers, contactors — the internal temperature rise can push past 40 °C, so the 81 A minimum figure may need to be de-rated. Plan for forced ventilation or a larger enclosure if the panel ambient exceeds 40 °C.

Fieldbus integration and analog output

This soft starter supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — a full industrial Ethernet stack plus the legacy fieldbus. The PROFINET variant also supports PROFIenergy for coordinated energy management during idle phases. No separate communication module is needed for the standard protocols; the unit ships with the interfaces onboard. An analog output is configurable as 4-20 mA (default) or 0-10 V, parameterizable via the High Feature HMI. This lets the PLC read motor current or torque directly without a separate transducer — useful for condition monitoring or load profiling on a conveyor line.

Mounting and panel fit — 306 x 185 x 203 mm

The 3RW5236-6AC05 measures 306 mm high, 185 mm wide, and 203 mm deep — a substantial unit that requires screw fixing to the backplate. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm to the side, and 0 mm backward (flush to the mounting surface). The 100 mm top clearance is critical for natural convection cooling — a common oversight that leads to nuisance thermal trips in enclosed panels.

Compliance and approvals — CE, UL, CSA

The 3RW5236-6AC05 carries CE marking, UL approval, and CSA approval. Shock resistance is 15 g for 11 ms, dropping to 12 g if contact lifting is a concern.

Frequently asked questions

What is the 3RW5236-6AC05 used for?

This SIRIUS soft starter is used to ramp up and ramp down three-phase induction motors, reducing inrush current and mechanical stress during start and stop. Typical applications include pumps, fans, conveyors, and compressors in industrial control panels. The 81 A minimum rating suits motors in the 30-50 kW range at 400 V.

What trip classes does the 3RW5236-6AC05 support?

It supports CLASS 10A (default), 10E, and 20E per IEC 60947-4-2. Class 10A provides a 10-second thermal limit at 7.2× rated current; Class 20E doubles that window for high-inertia loads. The setting is parameterized via the built-in interface.