Siemens 3RW5243-2TC05 — Soft Starters

Siemens 3RW5243-2TC05 SIRIUS Soft Starter, 90 A, 200-600 V

MPN3RW5243-2TC05
Active

Siemens SIRIUS 3RW5243-2TC05 soft starter, 90 A minimum, 200-600 V, Class 10A/10E/20E, PROFIBUS/Modbus RTU/Modbus TCP/EtherNet/IP/PROFINET, screw fixing, 203x210x393 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5243-2TC05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5243-2TC05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)110 kW
Rated motor power at 230 V (40 °C)55 kW
Rated operational current at 40 °C364 A
Rated operational current at 50 °C322 A
Rated operational current at 60 °C294 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)2 979 W

Control & Connection

3RW5243-2TC05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5243-2TC05 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5243-2TC05 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5243-2TC05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5243-2TC05 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5243-2TC05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Trip class and motor protection — what the 10A/10E/20E rating means for your start profile

The 3RW5243-2TC05 is a SIRIUS soft starter rated for a minimum motor current of 90 A across a 200-600 V supply range. Its trip class is configurable between CLASS 10A (default), 10E, and 20E per IEC 60947-4-2 — this sets the thermal overload curve that protects the motor during start. A Class 10A trip clears in 10 seconds at 7.2× FLA, matching standard squirrel-cage motors with normal inertia; 10E extends that window for extended-start applications like centrifuges, and 20E covers high-inertia loads such as crushers or long conveyors.

Fieldbus connectivity — PROFIBUS, Modbus, EtherNet/IP, and PROFINET on one unit

This soft starter ships with onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard communication — no separate gateway module needed for most line integrations. PROFINET supports PROFIenergy in conjunction with the standard communication module, allowing the drive to shed idle loads during production pauses. The Modbus TCP and EtherNet/IP stacks share the same physical port, so the commissioning engineer selects the protocol via the parameter menu without a hardware swap.

Mounting and clearance — screw-fixed chassis with defined air gaps

Fastening method is screw fixing to the backplate; the unit measures 210 mm wide, 393 mm high, and 203 mm deep. Clearance requirements are specified: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, and 5 mm at the side. The mounting position allows a vertical surface with ±90° rotation and ±22.5° tilt forward/backward, giving the panel builder flexibility in enclosure layout while maintaining the airflow path for the heatsink.

Ambient derating and operating envelope

The unit carries a service factor of 1, meaning no built-in overload margin beyond nameplate — the trip class settings handle the thermal protection. Shock resistance is 15 g for 11 ms, with potential contact lifting noted at 12 g / 11 ms, which matters for installations on vibrating machinery or near crushers.

Approvals and compliance — UL, CSA, CE, pollution degree 3

Approved under UL, CSA, and CE marking schemes. The pollution degree is rated 3 per IEC 60947-4-2, meaning it tolerates conductive pollution or dry non-conductive pollution that becomes conductive due to condensation — typical for industrial control panels without climate control. The minimum load is 15% of the smallest settable Ie, so the soft starter can handle lightly loaded motors without nuisance tripping.

Application-specific features — pump ramp down and soft torque

Pump ramp down is included, which gradually reduces the voltage to the motor during stop to eliminate water hammer in pumping systems. Soft torque is also available, reducing mechanical stress on the load during start. Remote reset is possible by cycling the 24 V control supply voltage. An error logbook is available only with special accessories — the base unit does not store fault history without the optional memory module.

MPN
3RW5243-2TC05