Skip to main content
Siemens 3RW5243-2TC14 — Soft Starters

Siemens 3RW5243-2TC14 SIRIUS Soft Starter, 90 A min

MPN3RW5243-2TC14
Active

Siemens SIRIUS 3RW5243-2TC14 soft starter, hybrid switching device, 90 A minimum, 200-480 V, Class 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP/PROFINET, screw fixing, 393x210x203 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5243-2TC14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5243-2TC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)110 kW
Rated motor power at 230 V (40 °C)55 kW
Rated operational current at 40 °C364 A
Rated operational current at 50 °C322 A
Rated operational current at 60 °C294 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)2 979 W

Control & Connection

3RW5243-2TC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5243-2TC14 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5243-2TC14 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5243-2TC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5243-2TC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5243-2TC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

SIRIUS 3RW5243-2TC14 — soft starter for motor starting duty

The Siemens 3RW5243-2TC14 is a SIRIUS-brand hybrid switching device — a soft starter rated for a minimum operating current of 90 A and a supply voltage range of 200 to 480 V (50/60 Hz). It offers programmable trip classes CLASS 10A (default), 10E, and 20E per IEC 60947-4-2, giving you the flexibility to match the thermal overload protection to the starting profile of your motor — pump, fan, or conveyor. On the fieldbus side, this unit supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard, plus PROFIenergy for coordinated energy management in automated lines.

Panel fit and thermal derating

The enclosure measures 393 mm high by 210 mm wide by 203 mm deep and is mounted via screw fixing to a vertical surface. The mounting position allows ±90° rotation and ±22.5° tilt front-to-back, which helps when you are squeezing it into a crowded panel. Minimum clearance around the unit: 100 mm above, 75 mm below, 10 mm forward, 5 mm to the sides, and 0 mm backward — the back can sit flush against the panel wall. Plan your gland plate layout accordingly. If the panel ambient runs warm, you need to account for that in the current setting.

Sourcing and lifecycle status

Certifications include CE, UL, and CSA — so it is accepted in European, US, and Canadian installations without additional paperwork.

Frequently asked questions

What is the 3RW5243-2TC14 used for?

It is a soft starter for three-phase induction motors, providing controlled acceleration (including soft torque and pump ramp-down) and programmable overload protection via trip classes 10A, 10E, or 20E. Typical applications include pumps, fans, conveyors, and compressors in industrial panels.

MPN
3RW5243-2TC14