Siemens 3RW5244-2AC14 — Soft Starters

Siemens 3RW5244-2AC14 Soft Starter, 100 A, 200-480 V

MPN3RW5244-2AC14
Active

Siemens SIRIUS 3RW5244-2AC14 soft starter, 100 A minimum, 200-480 V, Trip Class 10A, PROFIBUS/Modbus/EtherNet/IP/PROFINET, screw fixing, 203 x 210 x 393 mm.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5244-2AC14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5244-2AC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)132 kW
Rated motor power at 230 V (40 °C)75 kW
Rated operational current at 40 °C433 A
Rated operational current at 50 °C381 A
Rated operational current at 60 °C346 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)3 188 W

Control & Connection

3RW5244-2AC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5244-2AC14 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5244-2AC14 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5244-2AC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5244-2AC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5244-2AC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Panel fit and mounting — 203 x 210 x 393 mm

The 3RW5244-2AC14 measures 203 mm deep, 210 mm wide, and 393 mm high — a substantial frame that needs a backplate cutout sized for screw fixing. Clearance requirements: 100 mm above, 75 mm below, 10 mm in front, 0 mm behind, 5 mm at the sides — plan the gland plate and busbar runs accordingly.

Motor protection and starting profile — Trip Class 10A default

The soft starter is set to Trip Class 10A by default, per IEC 60947-4-2, meaning it allows a 10-second overload at 7.2× rated current before tripping — standard for starting most squirrel-cage motors without nuisance trips. Minimum load is 15% of the smallest settable Ie — so if you're running a motor well below 100 A, the starter still regulates current down to that floor. Soft torque and pump ramp down are built in — reduces mechanical shock on belts, gears, and piping during start and stop.

Fieldbus and control — PROFIBUS, Modbus, EtherNet/IP, PROFINET

The starter ships with PROFIBUS onboard, plus Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard — no extra communication module needed for most networks. PROFIenergy is supported when used with the PROFINET standard communication module — allows coordinated power-down during idle periods in automated lines. Analog output is configurable as 4-20 mA or 0-10 V (via the High Feature HMI) — feeds motor current or load signal to a PLC or panel meter.

UL, CSA, and CE markings are confirmed — accepted for panel builds in North America and the EU without additional certification.

Frequently asked questions

What compliance documentation does Siemens provide for the 3RW5244-2AC14?

The soft starter carries UL, CSA, and CE markings — documentation for RoHS and REACH is typically included with the unit or available on request.